Accton Technology 1500 manual Control Menu, Hub Port Backup Port Push Button

Models: 1500

1 98
Download 98 pages 903 b
Page 59
Image 59

EtherHub 1500 System User’s Guide

Control Menu

Hub

Port

Backup Port

Push Button

Includes hub description and commands to isolate/reattach network connection, or assign hub to a specified segment.

Includes port description and command to enable/disable selected port.

Defines master/slave port pairs used for emergency backup.

Enables/disables external Configure button on selected hub.

Parameter

Hub ID

Position

Name

Status

Segment

Type

Firmware Ver.

Configuring Hub Parameters

Use the Hub command from the Control menu to configure any hub in the stack. (Select the required hub using the <F4> and <F5> function keys.) This menu provides a brief description of the selected hub, and also allows you to isolate/reattach the hub from the network.

Description

Hub identifier within the stack. (Up to 10 hubs may be connected via the management channel.) Note that hub IDs can only be assigned using the Configure button as described later in this chapter.

The physical position in the stack.

Any user-defined name for the selected hub.

The stack connection may be set to ISOLATED or ATTACHED. Note that the Isolated LED will be lit if the hub is isolated. (Although the status of OTHER is provided, this is for internal use only.)

Attach the hub to a specified segment. The appropriate Segment icon will light up to show that the hub has been connected.

Indicates hub type as EH1501s, or EH1502s (Master or Slave).

Indicates the current firmware version number.