EtherHub 1500 System User’s Guide

Diagnostic function

Active LEDs: PARTITION/DISABLE LED 2 (EtherHub-16i+)

PARTITION/DISABLE LED 3 (EtherHub-16mi+)

LINK/TRAFFIC LED(labeled Diag)

Enabling the Diagnostic function will activate diagnostic tests similar to the one performed upon power on. For diagnostic test details, refer to the section on Diagnostic Tests earlier in this chapter. After succesfully completing Diagnostics, the system returns to normal operation.

LED

LINK/TRAFFIC LED 2 or 3

PARTITION/DISABLE LED 2 or 3

Reset function

Activity

BLINKING

BLINKING

Selection

Enable Diagnostic function Stop Diagnostic function

Active LEDs: PARTITION/DISABLE LED 3 (EtherHub-16i+)

PARTITION/DISABLE LED 4 (EtherHub-16mi+)

LINK/TRAFFIC LED (labeled Reset)

Activating the Reset function will revert all selections (made using the Configure button or by management software) to factory default settings. To avoid unintentionally resetting the hub, after you enable the Reset function using standard procedures, use short presses on the Configure button to light LINK/TRAFFIC LED 15 and then use a long press to confirm your action.

LED

LINK/TRAFFIC LED 3 or 4

PARTITION/DISABLE LED 3 or 4

Activity

BLINKING

BLINKING

Selection

Enable Reset function Stop Reset function

ΦThere are some selections made during configuration or system management which remain in memory even if the hub is powered off and on. For example, a port disabled using SNMP management software (e.g., AccView/Open) will remain disabled even if the hub is powered off and then on. It can only be enabled by using the management software or resetting the hub.