11. Connecting External Signal Control

If external signal(s) are required, the addition of a relay (not supplied) will be necessary.

Please consult your local electrician.

When a signal is activated the internal contacts close completing the circuit. These internal contacts are "dry" and supply no voltage. Voltage applied to these contacts must not exceed 30 volts. An external relay must be used to activate signaling devices.

Recommended Relays: (Or similar line voltage switching relays)

Available at W. W. Grainger

 

 

HoneyWell

#RA89A1074

Grainger #2E866

Dayton

#809A-189

Grainger #2E553

 

120 VAC

Nuetral

 

ES1000

Internal

Relay

30V

Class 2

2 1

External

Relay

3

External

4

Signal

 

Connections shown for Dayton 2E553. Add jumper from terminals 1 to 3.

CAUTION: Disconnect the ES1000 from the AC Power before connecting the External Signal Relay. Improper connection may cause a malfunction of the unit.

Also make sure to secure wires with the wire clamp.

1 Remove the cover of the battery compartment on the back of the unit by pushing down the top side of the cover, and then release it from the two clasps.

66