PL15 - ANTI-WRINKLE TIMING

1.Guard Delay Time (GdLY)

This program controls the dwell (stop) time and activation of anti-wrinkle “Guard On Time” (“Gont”). The dwell (stop) time can be programmed from a minimum of 1 minute to a maximum of 9 minutes in 1 minute increments.

2.Guard On Time (Gont)

The setting controls the amount of time that the basket (tumbler) will turn, without heat, when the Anti-Wrinkle is active (“Grd”). The “Guard On Time” (“Gont”) is programmable from a minimum of 1-second to a maximum of 99-seconds in 1-second increments.

PL16 - ACTIVE GUARD TIME (AGt)

This program controls the maximum time that the Anti-Wrinkle Program will be active and is programmable from a minimum of 1 minute to a maximum of 99 minutes in 1 minute increments.

PL17 - “A” and “b” FACTORS

This location will include the “Auto-Cycle” parameters. These parameters are necessary to allow the Phase 5 microprocessor controller (computer) to calculate the percentage of dryness in the basket (tumbler). The “A” Factor is adjustable from 1 to 99.

These parameters are the factors that the Phase 5 microprocessor controller (computer) utilizes when programmed for an “Automatic Drying Cycle.” The “A” Factor slope program, pertains to the thermal characteristic of each model dryer. The “b” Factor, heat loss (offset) program, also pertains to the thermal characteristics of each model dryer. This factor setting is dependent upon the model dryer and type of heating unit.

The “Aand b” Factors have not been preprogrammed by the factory and must be programmed if the Phase 5 microprocessor controller (computer) programming is changed to be used in the Automatic Mode. The “A” and b” Factors must be programmed for the particular dryer model and heating unit as shown in the “A” and b” Factor (parameter) table on page 60 of this manual.

24

Page 26
Image 26
ADC AD-26, WDA-540, AD-295, AD-540 user manual PL15 ANTI-WRINKLE Timing, PL16 Active Guard Time AGt, PL17 a and b Factors