R. PROGRAM LOCATION 15 (PL15)

Anti-Wrinkle Timing

Refer to Section V for instructions on entering program locations.

PL15

Perm Press

GdLY

(Wait 3-Seconds)

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “GdLY,” guard delay time for 3-seconds and then time programmed. If no change, press “Perm Press” key, otherwise press “HI” or “LO” keys and then “Perm Press” key.

Time Decrease

LO Temp

("Hold In" to Accelerate)

2

Perm Press

Gont

Time Increase

HI Temp

("Hold In" to Accelerate)

(Wait 3-Seconds)

Time Decrease

LO Temp

20

("Hold In" to Accelerate)

Time Increase

HI Temp

("Hold In" to Accelerate)

Proceed to next location

to be changed

Perm Press

PL16

To exit program mode, open program switch

Display will read “Gont” anti-wrinkle on time for 3-seconds and then time programmed. If no changes, press “Perm Press” key, otherwise press “HI” or “LO” keys and then “Perm Press” key.

Summary: Guard delay time is programmable from 1 to 9 minutes. Guard on time is programmable from 1 to 99-seconds.

49

Page 51
Image 51