K. PROGRAM LOCATION 08 (PL08)

Perm Press Cool Down Temperature/Time

Refer to Section V for instructions on entering program locations.

PL08

 

Continued from J.

 

 

Perm Press

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PPCd

(Wait 3-Seconds)

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “PPCd,” “Perm Press” key cool down status for 3-seconds and then cool down temperature and time programmed. If no changes, press “Perm Press” key twice. Otherwise, press “HI” or “LO” keys and then “Perm Press” key.

Temperature Decrease

LO Temp

·100·3

Perm Press

Temperature Increase

HI Temp

Time Decrease

LO Temp

Proceed to next location

to be changed

100·3

Perm Press

PL09

Time Increase

HI Temp

To exit program mode, open program switch

Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten-degree increments or from a minimum 21° C to a maximum of 88° C in five-degree increments. For the AD-26 and AD-295any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71° C in five-degree increments.

Cool down is programmable from 0 to 9 minutes.

42

Page 44
Image 44
ADC WDA-540, AD-295, AD-26, AD-540 user manual Program Location 08 PL08, Perm Press Cool Down Temperature/Time