TEMPERATURE DISPLAY

This program selection enables the temperature in the dryer to be viewed (°F or °C) either while the dryer is off or running. This service feature shows that the dryer is maintaining the selected temperature.

DIAGNOSTICS

ALL major circuits, including door, microprocessor temperature sensor, heat, and motor circuits are monitored. There are also indicators installed on the outputs of each relay to easily identify failures, and the door switch has an indicator installed on the Phase 5 microprocessor controller (computer) to help indicate failure.

AUTOMATIC DRYTIME

This program selection allows the dryer to run up to a specific time. During the “AUtO” mode or “FrEE” dry mode this program is only designed to limit the dryer’s operation during the drying cycle.

ROTATIONALSAFE GUARD (Optional)

This program monitors the rotation of the basket (tumbler). If the basket (tumbler) is not rotating, the Phase 5 coin microprocessor controller (computer) will disable ALL outputs, an audible tone (buzzer) will sound, and an error message will be displayed. This program selection can be programmed to be in the inactive mode.

BATTERYBACKUP (Optional)

This feature allows the Phase 5 coin microprocessor controller (computer) to maintain its operating status should a momentary power interruption occur while the dryer cycle is in progress.