G. PROGRAM LOCATION 04 (PL04)

HI Temp cool down temperature/time

Refer to Section V for instructions on entering program locations.

Continued from F.

Temperature Decrease

LO Temp

PL04

Perm Press

HICd

(Wait 3-Seconds)

·100·2

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “HICd,” HI Temp cool down status for 3-seconds and then the actual temp and time programmed.

If no change press “Perm Press” key twice, otherwise press “HI” or “LO” keys and then “Perm Press” key.

Temperature Increase

HI Temp

Perm Press

Time Decrease

Time Increase

LO Temp

100·2

Perm Press

HI Temp

PL05

Proceed to next location

to be changed

To exit program mode, open program switch

Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments.

For the AD-26 and AD-295any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71° C in five-degree increments.

Cool down is programmable from 0 to 9 minutes.

38

Page 40
Image 40
ADC WDA-540, AD-295, AD-26, AD-540 Program Location 04 PL04, HI Temp cool down temperature/time, Time Decrease Time Increase