38
G. PROGRAM LOCATION 04 (PL04)
HI Temp cool down temperature/time
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “HICd,” HI Temp
cool down status for 3-seconds and then
the actual temp and time programmed.
If no change press “Perm Press” key twice,
otherwise press “HI” or “LO” keys and
then “Perm Press” key.
Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten
degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from
a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.
Cool down is programmable from 0 to 9 minutes.
PL04
HICd
Perm Press
·
100
·
2HI Temp
Perm Press
LO Temp
Refer to
Section V
for instructions
on entering program locations.
(Wait 3-Seconds)
Continued from F.
100
·
2
LO Temp HI Temp
Perm Press
PL05
Proceed to next location
to be changed To exit program mode,
open program switch
Temperature Decrease Temperature Increase
Time Decrease Time Increase