Formula: (AFAt/AtSt)(tFAS) = Vended Time for “AFAt” (25¢/35¢) (14 minutes) = 10 minutes

Settings: PL09

(LCdE)

10

PL10

(rCdE)

25

PL11 (tFAS)

14

PL12 (AtSt)

35

PL13 (AFAt)

25

ROTATIONAL SAFE GUARD - OPTIONAL(nSEn)

This program monitors the rotation of the basket (tumbler) and works in conjunction with a special sensor (optional) located at the rear basket (tumbler) support area of the dryer. If the basket (tumbler) is not rotating (i.e., broken belt, failed motor, etc.), the Phase 5 microprocessor controller (computer) will disable ALL outputs (shut the dryer down), the buzzer (tone) will sound (for time programmed), and the light emitting diode (L.E.D.) display will read a failure message “SEFL” (Rotational Sensor Circuit Failure). The failure code must be cancelled manually by opening and closing the Program Switch (PS). This program selection (option) can be programmed to be active (“SEn”) or inactive (“nSEn”).

NOTE: This parameter is programmed by the factory to be inactive (“nSEn’) unless the dryer was manufactured with optional “rotational sensor.”

PL02 - PERCENT DRY (PdrY)

When in the automatic mode, the dryer will run until the preset level of dryness has been reached or until the Maximum Auto Dryness Time (Adrt) has been reached or until the Maximum Auto Dryness Time (Adrt) has expired. The dryness level is programmable from a minimum of ninety percent (90%) to a maximum of one hundred percent (100%).

NOTE: Due to humidity, atmospheric pressure, water retention in the garment etc., the desired “Percent Dry” (“PdrY”) may vary. It is suggested that the owner determine which level of dryness (90% to 100%) is best suited for his/her application by experimenting with a few test loads.

PL03 - HIGH TEMPERATURE (HI°F)

The high operating temperature is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree increments.

For the AD-26 and AD-295any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71° C in five-degree increments.