J. PROGRAM LOCATION 07 (PL07)

Perm Press Temp

Refer to Section V for instructions on entering program locations.

Temperature Decrease

LO Temp

PL07

Perm Press

PP°F

(Wait 3-Seconds)

150F

Perm Press

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “PP°F,” “Perm Press” temperature key status for 3-seconds and then actual temperature programmed. If no change, press “Perm Press” key otherwise press “HI” or “LO” keys

and then “Perm Press.”

Temperature Increase

HI Temp

Automatically goes into PL08 Program without PL08 Display Mode

Continued on next page

Summary: Perm Press Temp is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree increments. For the AD-26 and AD-295any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71° C in five-degree increments.