TIME FOR AMOUNT TO START

This program retains the time the owner wishes to vend. The feature allows any additional purchase that is made to be calculated to the second. There is no calculation necessary by the owner. The Phase 5 coin microprocessor controller (computer) calculates the vended time.

ACCUMULATIVE COIN

This program selection requires that a specific value of coin(s) be inserted for additional time, programmable for any minimum amount.

COIN COUNT

The number of coins inserted, including a separate display program for optional dual coin acceptors, can be viewed through the Phase 5 computer’s light emitting diode (L.E.D.) display.

BAD COIN LOCKOUT

Each coin is monitored. Should someone tamper with the coin acceptor or attempt to insert a foreign object, the microprocessor controller (computer) will “LOCKOUT” and will not accept any entries until the reset time has elapsed (approximately 15-seconds). Once the reset time has expired, the microprocessor controller (computer) will automatically reset itself for the next coin entry.

TEMPERATURE CONVERSION

When the temperature conversion status is changed (i.e. from °F to °C), the Phase 5 coin microprocessor controller (computer) will automatically convert ALL temperature related programs/parameters from Fahrenheit to Celsius and vice versa. The Phase 5 coin microprocessor controller (computer) will perform this conversion within 1° F (2° C). The programs affected are:

1.Temperature Display Mode

2.Temperature Selections

3.Cool Down Temperatures

DRYING TEMPERATURES

Any of the three (3) temperature selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree increments. Actual temperature programs are displayed at time of programming for verification.

For the AD-26 and AD-295any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 170° F in ten-degree increments, or from a minimum of 38° C to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71° C in five-degree increments.

5

Page 7
Image 7
ADC AD-540, WDA-540, AD-295, AD-26 user manual Time for Amount to Start