COOL DOWN TIME
ALL three (3) temperature selections are programmable from a minimum of 0 minutes to a maximum of 9
minutes in 1 minute increments.
COOL DOWN TEMPERATURES
In the automatic or free dry modes, the cool down cycle termination is programmable from a minimum of 70° F
to a maximum of 190° F in ten-degree increments or from a minimum of 21° C to a maximum of 88° C in
five-degree increments.
AUTOMATIC MODE (Patent No. 4,827,627)
This program selection uses ADC’s patented Auto-Dry cycle. The microprocessor controller (computer) will
calculate the percent of the dryness and read “donE” when complete. The Phase 5 coin microprocessor
controller (computer) can be programmed to have a maximum time for the “Auto Mode.” The Automatic Cycle
(mode) can be used in either the “Free Dry” Mode or the “Coin” Mode.
ANTI-WRINKLE
This program selection helps keep permanent press items wrinkle free when they are not removed from the
dryer promptly at the end of the drying and cooling cycles. The Anti-Wrinkle program settings are:
1. Guard Delay Time...................... 1 to 9 minutes
2. Guard On Time........................... 1 to 99-seconds
3. Active Guard Time..................... 1 to 99 minutes
FREE DRY MODE
In this program selection, the dryer can be started without the insertion of coins by simply pressing any one of the
three (3) temperature selections. When set in the “Free Dry” Mode, the Phase 5 coin microprocessor controller
(computer) can also be programmed to run with an Automatic Cycle (percent of dryness) or with a Timed Cycle.
If the “Free Dry” program is utilized, the computer’s light emitting diode (L.E.D.) display will cycle back and
forth between “FILL” to “FrEE,” unless otherwise programmed.
L.E.D. FLASH DISPLAY
Programmable to allow the L.E.D. readout to display a choice of “FILL” (no cycle in progress), “Amount To
Start” (i.e., 25¢), or, in the case of free dry, “FrEE.” This program selection also allows the L.E.D. display to
flash back and forth every 2-seconds from “FILL” to “Amount To Start” or, in the case of free dry, from “FILL”
to “FrEE.”
AUDIBLE TONE
In this program selection, a tone (buzzer) will sound for each coin inserted, program entry, or at the drying and
cooling cycles for a period of 5-seconds to indicate that the cycle is complete. Additionally, when in the
Anti-Wrinkle program, the tone (buzzer) will sound for 5-seconds at the end of the “Guard On Time.”