COOL DOWN TIME
ALL three (3) temperature selections are programmable from a minimum of 0 minutes to a maximum of 9 minutes in 1 minute increments.
COOL DOWN TEMPERATURES
In the automatic or free dry modes, the cool down cycle termination is programmable from a minimum of 70° F to a maximum of 190° F in
AUTOMATIC MODE (Patent No. 4,827,627)
This program selection uses ADC’s patented
ANTI-WRINKLE
This program selection helps keep permanent press items wrinkle free when they are not removed from the dryer promptly at the end of the drying and cooling cycles. The
1.Guard Delay Time ...................... 1 to 9 minutes
2.Guard On Time ........................... 1 to
3.Active Guard Time ..................... 1 to 99 minutes
FREE DRY MODE
In this program selection, the dryer can be started without the insertion of coins by simply pressing any one of the three (3) temperature selections. When set in the “Free Dry” Mode, the Phase 5 coin microprocessor controller (computer) can also be programmed to run with an Automatic Cycle (percent of dryness) or with a Timed Cycle. If the “Free Dry” program is utilized, the computer’s light emitting diode (L.E.D.) display will cycle back and forth between “FILL” to “FrEE,” unless otherwise programmed.
L.E.D. FLASH DISPLAY
Programmable to allow the L.E.D. readout to display a choice of “FILL” (no cycle in progress), “Amount To Start” (i.e., 25¢), or, in the case of free dry, “FrEE.” This program selection also allows the L.E.D. display to flash back and forth every
AUDIBLE TONE
In this program selection, a tone (buzzer) will sound for each coin inserted, program entry, or at the drying and cooling cycles for a period of
6