ACCUMULATIVE COIN (ACOn)

When this program mode (“ACOn”) is selected, additional time can only be achieved when the “Amount For Additional Time” (“AFAt”) PL13 has been inserted.

NOTE: When programming, to use theAccumulative Coin Mode (“ACOn”), the following parameters/ programs need to be checked and/or changed accordingly:

Settings: PL01

“ACOn” (“Accumulative Coin”)

PL13

“AFAt” (“Amount ForAdditional Time”)

(SINGLE COIN ACCEPTOR)

Example No. 1: Using a 25¢ coin acceptor with the desired “Amount To Start” (“AtSt”) being 50¢ for 24 minutes, the Phase 5 coin microprocessor controller (computer) would yield more time (24 minutes) only when an additional 50¢ is inserted. For this application, the “Time For Amount To Start” (“tFAS”) program (PL11) is determined as follows:

Formula: (AFAt/AtSt) (tFAS) = Vended Time for “AFAt” (50¢/50¢) (24 minutes) = 24 minutes

Settings: PL09 (LCdE)

25

PL11 (tFAS)

24

PL12 (AtSt)

50

PL13 (AFAt)

50

(DUAL COINACCEPTOR)

With a dual coin acceptor the “Time For Amount To Start” (“tFAS”) is determined as shown below:

Formula: (AFAt/AtSt) (tFAS) = Vended Time for “AFAt”

Example No. 1: Using a 10¢/25¢ dual coin acceptor the desired “Amount To Start” (“AtSt”) is 50¢ for 20 minutes and the “Amount for Additional Time” (“AFAt”) is set for 20¢ each additional 20¢ would yield 8 minutes.

Formula: (AFAt/AtSt) (tFAS) = Additional Vended Time (20/50) (20 minutes) = 8 minutes

Settings: PL09

(LCdE)

10

PL10

(rCdE)

25

PL11 (tFAS)

20

PL12 (AtSt)

50

PL13 (AFAt)

20

Example No. 2: If the dryer is equipped with a 10¢/25¢ dual coin acceptor and the desired “Amount To Start” (“AtSt”) is 35¢ for 14 minutes and the “Amount For Additional Time” (“AFAt”) is set for 25¢, each additional 25¢ inserted would yield 10 minutes.

20