F. PROGRAM LOCATION 03 (PL03)

HI Temp

Refer to Section V for instructions on entering program locations.

PL03

Perm Press

HI°F

(Wait 3-Seconds)

Location to be viewed/changed.

Press “Perm Press” key.

Display will read “HI°F,” “HI Temp” key status for 3-seconds and then the actual temperature programmed. If no changes, press “Perm Press” key otherwise press “HI” or “LO” keys and then “Perm Press” key.

Temperature Decrease

LO Temp

180F

Perm Press

Temperature Increase

HI Temp

Automatically goes into PL04

Program without PL04 Display

Mode

Continued on next page

Summary: HI Temp is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree increments.

For the AD-26 and AD-295any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to a maximum of 77° C in five-degree increments.

For the AD-540 and WDA-540any three (3) of the selections (HI/LO/PP) are programmable from a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71° C in five-degree increments.

37

Page 39
Image 39