ADC AD-295, WDA-540, AD-26, AD-540 user manual

Models: AD-540 AD-295 WDA-540 AD-26

1 66
Download 66 pages 16.96 Kb
Page 61
Image 61

NOTE: If the failure was elsewhere (i.e. dryer’s door switch circuit) the light emitting diode (L.E.D.) display would read “door” if a keyboard (touch pad) entry was attempted. If the display L.E.D. indicators are on, and the door L.E.D. indicators are on, and the door L.E.D. input and motor/heat output L.E.D.s are on, yet the motor and/or heat is not active (on); then the problem is not the door switch on the Phase 5 microprocessor controller (computer), the problem is elsewhere in the dryer.

2.“HEAT” - Output L.E.D. Indicator - if the dryer is started and there is no heat, yet the microprocessor controller (computer) L.E.D. display heat indicator dot is on, but the heat output L.E.D. indicator is off, then the fault is in the Phase 5 microprocessor controller (computer) itself. If both the display heat output L.E.D. indicator are on, then the problem is elsewhere (external of the microprocessor controller (computer).

3.“MTR” (motor) - Output L.E.D. Indicator - if the dryer is started and the motor is not operating, yet both the microprocessor controller (computer) L.E.D. display motor indicator dot and “DOOR” input L.E.D. indicator are on, but the “MTR” output L.E.D. indicator is off; then the fault is in the Phase 5 microprocessor controller (computer) itself. If the motor is not operating and the “MTR” output indicator is on, then the problem is elsewhere (external of the microprocessor controller [computer]).

59

Page 61
Image 61
ADC AD-295, WDA-540, AD-26, AD-540 user manual