C–5 RS3100007 Rev. 0
Before You Install
Motor Overload Protector
Internal overload protector automatically stops motor in
event of overload. Overload protector resets in
approximately 3 minutes and motor automatically
restarts. If overload protector stops motor again, quit
using washer and call service technician.
Loading wash tub too full may result in motor overload.
See
Washing Guide
for proper load size information.

Water Supply Requirements

WARNING
!
Explosive hydrogen gas may be produced in a hot
water system that has not been used for two weeks
or more. Before using washer, if hot water system
has not been used for such a period, turn on all hot
water faucets and let water flow for several minutes to
release accumulated hydrogen gas. Hydrogen gas is
flammable: do not smoke or use an open flame when
flushing water lines.
Water supply faucets must fit standard 3/4" (19.05 mm)
female garden hose couplings. Do not use slip-on or
clamp-on connections.
NOTE: Water supply faucets should be easily
accessible and turned off after extended use.
Optional longer inlet hoses are available at extra cost, if
hoses supplied with washer are not long enough for
installation. Order hoses as follows:
No. 20617 Inlet Hose, 8 feet (2.44 m)
No. 20618 Inlet Hose, 10 feet (3.05 m)
Water Pressure
Static pressure measured at faucet must be 20–120
pounds per square inch (138 to 827 kPa). Water
pressure under 20 pounds per square inch (138 kPa)
results in extended washer fill time.

Electrical Requirements

Washer requires 120 volt, 15 amp, 60Hz power supply
and 3-prong grounding plug. Refer to serial plate for
specific requirements. Wiring diagram is located in
control hood.

WARNING

!
To avoid risk of personal injury or death due to
electrical shock:
Observe all local codes and ordinances.
Disconnect electrical power to unit before
servicing.
Ground appliance properly.
Check with a qualified electrician if you are not
sure this appliance is properly grounded.
DO NOT ground to gas line.
DO NOT ground to cold water pipe if pipe is
interrupted by plastic, non-metallic gaskets, or
other insulating (non-conducting) materials.
DO NOT modify plug on power cord. If plug does
not fit electrical outlet, have proper outlet
installed by qualified electrician.
DO NOT have a fuse in the neutral or ground
circuit. A fuse in the neutral or ground circuit
could result in an electrical shock.
DO NOT use an extension cord with this
appliance.
DO NOT use an adapter plug with this appliance.
DO NOT pinch power cord.
Grounding Instructions
For safety, washer must be grounded. All washer power
supply cords are equipped with 3-prong grounding plug.
Plug on cord must be plugged into appropriate outlet
that is properly installed and grounded in accordance
with all local codes and ordinances. Do not modify plug
on washer cord. If plug will not fit outlet, have qualified
electrician install proper outlet.
Do not remove warning tag from power cord.

WARNING

!
To avoid risk of personal injury or death due to
electrical shock:
Grounding wires and wires colored like grounding
wires are NOT to be used as current carrying
conductors.
Standard accepted color coding for ground wires is
green or green with a yellow stripe.
Water supply
faucets
Cold water connection
Hot water
connection
Water mixing
valve
Water
inlet hoses