AMX NXD-700Vi manual Wiring the NXA-AVB/ETHERNET connectors and cables, Nxa-Avb/Ethernet

Models: NXD-700Vi

1 232
Download 232 pages 24.26 Kb
Page 19
Image 19

NXA-AVB/ETHERNET Breakout Box

 

Indirect

Ethernet In

Mic Out

 

 

Line Level out

 

Connect

 

(to amplifier

 

 

 

(RJ-45)

 

 

(4-pin captive-wire)

 

 

 

 

 

 

 

 

 

 

12 VDC power

 

 

 

 

 

Video In

 

Audio In

or VOL card)

 

 

 

 

 

 

 

supply

 

 

 

 

 

(BNC)

 

(6-pin captive-wire)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(rear)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NXA-AVB/ETHERNET

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

Breakout Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(front)

 

supplied via

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NXA-AVB box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet

Audio/Video

 

 

12 VDC power

 

 

 

 

 

 

 

 

 

 

(CAT5)

(CAT5)

 

 

 

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or

Direct

Connect

NXD/T Video-capable

Touch Panels

FIG. 5 Sample wiring configuration on video-capable panels using this breakout box

A 12 VDC-compliant power supply can also directly provide power through the unit to a target Modero panel. FIG. 6 shows a sample wiring configuration for a non-video capable Modero panel.

Direct connect

12 VDC power

supply

Ethernet

(CAT5)

 

 

 

Audio (CAT5)

 

 

 

between the

 

 

 

 

 

 

 

 

 

 

NXA-AVB/ETHERNET

 

 

 

 

 

 

 

Breakout Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NXD/T Non-video capable

Touch Panels

FIG. 6 Sample wiring configuration using non-video capable Modero panels

The breakout box unit can be mounted on either a horizontal flat surface or into an equipment rack (by removing the front screws and attaching it to an optional AC-RK). The power supply being used on the NXA-AVB/ETHERNET is dependant on the power requirements of the target touch panel.

Use a standard CAT5 Ethernet cable to provide both communication and 10/100 network connectivity between the panel, NXA-AVB/ETHERNET, NetLinx Master, and the network.

Wiring the NXA-AVB/ETHERNET connectors and cables

The inputs and outputs on the breakout box are separated into front and rear connectors. The rear connectors are used to input external signals. The front connectors are used to communicate signals between the NXA-AVB/ETHERNET and a target Modero panel. FIG. 7 provides a layout of the wiring connection both into and from the breakout box.

7" Modero Widescreen Touch Panels

9

 

 

Page 19
Image 19
AMX NXD-700Vi manual Wiring the NXA-AVB/ETHERNET connectors and cables, Nxa-Avb/Ethernet