Upgrading Modero Firmware

6.Press the Back button to return to the Protected Setup page and press the on-screen Reboot button to restart the panel and save any changes.

Step 3: Verify and Upgrade the panel firmware via an IP

1.Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one.

2.Right-click the associated System number (from the Workspace window) and select Refresh System to detect of all devices on the current system, establish a new connection to the Master, and refresh the System list with devices on that system.

3.After the Communication Verification dialog window verifies active communication between the PC and the Master, verify the panel appears in the OnLine Tree tab of the Workspace window (FIG. 51). The default Modero panel value is 10001.

Showing the NetLinx Master firmware version and device number

Showing the current Modero panel firmware version and device number

Shows NetLinx Studio version number

FIG. 51 NetLinx Workspace window (showing connected Modero panel)

The panel firmware is shown on the right of the listed panel.

4.If the panel firmware being used is not current, download the latest Kit file by first logging in to www.amx.com and then navigate to Tech Center > Firmware Files and from within the Modero section of the web page locate your Modero panel.

The latest NXD-700Vi firmware kit file is now panel-specific.

Only NXD-700Vi firmware should be loaded onto ithis specific panel type. This new firmware also provides both backwards compatibility with the previous 802.11b cards and new security protocols for the new 802.11g wireless CF card.

5.Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you have downloaded the Modero Kit file to a known location.

6.From within Studio, select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (FIG. 52). Verify the panel’s System and Device number values match those values listed within the System folder in the OnLine Tree tab of the Workspace window.