Section 8 Device Message Details

:SOURce :TELecom : OFFSet <numeric>

Command type

Parameter

Function Example of use

Sequential command

<numeric> = <DECIMAL NUMERIC PROGRAM DATA> -50 to +50 ... step 0.I

Performs the frequency offset setting.

Sets the value of frequency offset at +25.

>: SOURce : TELecom : OFFSet 25

:SOURce : TELecom :OFFSet?

Command type

Sequential command

Response

<NR 1 NUMERIC RESPONSE DATA>

 

-50 to +50 ... step 0.1

Function

Makes a query of the value of frequency offset.

Example of use

> : SOURce : TELecorn : OFFSet?

<-25

:SOURce : JITTer : RANGe <range>

Command type

Sequential command

Parameter

<range> = C H A R A C T E R PROGRAM DATA>

 

UI3200

3,200 UIPP

 

UI1600

1,600 UIPP

 

UI800

800 UIPP

 

U180

8 0 UIPP

 

U140

40 UIPP

 

UI20

20 UIPP

 

UI05

0.5 UIPP

Function

Performs setting of the transmission jitter generation range.

Restriction

Effective when transmission jitter is generated.

 

Restrictions on setting apply depending on the Bit Rate.

Bit Rate

UI Range

10 G

3.200. 80, 0.5 UI

Example of use

Sets the transmission jitter generation range at 0.5 UIPP.

 

> : SOURce : JITTer : RAN& UI05

Page 88
Image 88
Anritsu MP1777A Device Message Details SOURce TELecom OFFSet numeric, SOURce TELecom OFFSet?, SOURce JITTer RANGe range