Section 8 Device Message Details

:SENSe : TELecom : RANGe <range>

Command type Parameter

Function Example of use

Sequential command

<range> = <CHARACTER PROGRAM DATA>

U14

..............4 UIPP

UI 1

..............1 UIPP

Sets the measurement range of receiving jitter.

Sets the measurement range of receiving jitter at 1 UIPP,

>: SENSe : TELecom : RANGe UIl

:SENSe : TELecom : RANGe?

Command type

Sequential command

Response

<range> = <CHARACTER RESPONSE DATA>

Function

Makes a query of receiving jitter measurement.

Example of use

> : SENSe : TELecom : RANGe?

 

< UII

: SENSe :TELecom : FlLTer <filter>

Command type

Sequential command

 

Parameter

<filter> = <CHARACTER PROGRAM DATA>

 

LP

LP

(80 M)

 

H P l L P

HPl+LP

(10 K to 80 M)

 

HPl SLP

HPI1+LP

(20 K to 80 M)

 

HP2LP

HP2+LP

(4 M to 80 M)

 

HP3LP

HP3+LP

(6 M to 80 M)

 

HPLP

HP+LP

( 12 K to 80 M)

 

HPSLP

HP'+LP

(50 K to 80 M)

Function

Performs filter setting.

 

Restriction

H P 1 + L P , H P l ' + L P setting is disabled w h e n the Bit Rate is set a t 2.5 G o r 5 G.

 

HP3+LP can be set only for Option 07.

Example of use

Sets the filter at HP'+LP, HPll+LP.

 

> : SENSe : TELecom : FILTer HPSLP

Page 92
Image 92
Anritsu MP1777A operation manual SENSe TELecom RANGe range, SENSe TELecom RANGe?, SENSe TELecom FlLTer filter