Anritsu MP1777A operation manual Device Message Details SOURce TELecom EQUAlizer boolean

Models: MP1777A

1 130
Download 130 pages 12.22 Kb
Page 86
Image 86

Section 8 Device Message Details

:SOURce : TELecom : EQUAlizer <boolean>

Command type

Sequential command

Parameter

<boolean> = <BOOLEAN PROGRAM DATA>

 

OFF or 0 ...... Equalizer OFF

 

ON or 1 ........ Equalizer ON

Function

Sets ON/OFF of the Jitter Setting Equalizer.

Example of use

Sets the Jitter Setting Equalizer ON.

 

> ; SOURce : TELecom : EQUAlizer ON

---

:SOURce :TELecom : EQUAlizer?

Command type

Sequential command

Response

<NR 1 NUMERIC RESPONSE DATA>

 

0

Equalizer OFF

 

1

Equalizer ON

Function

Makes a query of the setting status of the Jitter Setting Equalizer.

Restriction

None

 

Example of use

> : SOURce : TELecom : EQUAlizer?

<1

:SOURce : TELecom : CLOCk : SOURce <csource>

Command type

Sequential command

 

 

 

Parameter

<csource> = <CHARACTER PROGRAM DATA>

 

INTernal

Internal

 

 

LOCK-2MHB

2

MHz

(Balanced)

 

LOCK-2MHU

2

MHz

(Unbalanced)

 

LOCK-2MBB

2

Mbit/s

(Balanced)

 

LOCK-2MBU

2 Mbit/s

(Unbalanced)

 

LOCK-I SMH

1.5 MHz

(Unbalanced)

 

LOCK-1 SMB

1.5 Mhit/s

(Balanced)

 

EXTernal

External

 

 

LOCK-1 OM

Lock 1OM

(Balanced)

Function

Sets the clock source of the transmission signal.

Example of use

Sets the clock source of the transmission signal to internal.

>: SOURce : TELeconi : CLOCk : SOURce INTemal

Page 86