8.3 Device-Specific Commands

:SOURce : TELecom : BRATe <brate>

- -

Command type

Sequential command

 

 

Parameter

<brate> = <CHARACTER PROGRAM DATA>

 

 

(Standard)

 

(Option 05)

 

 

M2,488

2,488 Mbit/s

M3069

3,069 Mbit/s

 

M4,977

4,977 Mbit/s

M6138

6,138 Mbitls

 

M9,953

9, 953 Mbit/s

M12276

12,276 Mbitis

 

(Option 01)

 

(Option 06)

 

 

M2494

2,494 Mbitls

M2677

2,677 Mbitls

 

M4988

4,988 Mbit/s

M5355

5,355 Mbitls

 

M9977

9,977 Mbit/s

M 10709

10,709 Mbitls

 

(Option 02)

 

(Option 07)

 

 

M2666

'2,666 Mbit/s

M2578

2,578 Mbit/s

 

M5332

5,332 Mbitis

M5156

5,156 Mbit/s

 

MI0664

10,664 Mbit/s

MI0313

10,313 Mbit/s

 

(Option 03)

 

 

 

 

M3062

3,062 Mbit/s

 

 

 

M6125

6,125 Mbit/s

 

 

 

M12249

12,249 Mbit/s

 

 

Function

Sets the sign speed of transmission signal.

 

Restriction

Sending the command while the option above is not set results in a run time error.

 

When the same setting is established for the transmission and reception modules (Tx&Rx),

 

the reception Bit Rate will be set.

 

 

Example of use

Sets the sign speed of the transmission signal to 9,953 Mbitls.

>: SOURce : TELecom : BRATe M9953

:SOURce : TELecom : BRATe?

Command type

Sequential command

Response

<brate> = <CHARACTER RESPONSE DATA>

Function

Makes a query of the sign speed of the transmission signal.

Example of use> : SOURce : TELecom : BRATe?

<M9953