8.3 Device-Specific Commands

8.3.7STATus Subsystem

The STATUSsubsystem performs control (setting and display) of the status registers.

: STATUS

: PRESet

 

 

 

 

: OPERalion

[:EVENt]?

 

 

 

 

: CONDition?

 

 

 

 

: ENABle

 

<numeric>

 

 

: ENABle?

 

 

 

 

: PTRansition

 

<numeric>

 

 

: PTRansition?

 

 

 

 

: NTRansition

 

<numeric>

 

 

: NTRansition?

 

 

 

 

: INSTrument

[:EVENt]?

 

 

 

 

: CONDition?

 

 

 

 

: ENABle

<numeric>

 

 

 

: ENABle?

 

 

 

 

: PTRansition

<numeric>

 

 

 

: PTRansition?

 

 

 

 

: NTRansition

<numeric>

 

 

 

: NTRansition?

 

:STATus : PRESet

Command type

Sequential command

Parameter

None

Function

Initializes status registers.

 

See the Section 6 "Status Report".

Example of use

> : STATus : PRESet

:STATus : OPERation [:EVENt]?

Command type

Sequential command

Response

<numeric> = <NR 1 NUMERIC RESPONSE DATA>

 

0 to 32,767 ........ Sum (decimal digit) of event register bits

Function

Makes a query of the details of the event register of the OPERation status event register.

Example of use

When the INSTrument status register summary bit of the OPERation status event register is

 

ON.

 

> : STATus : OPERation : EVENt'?