B.4 Device Status at Power Activation

B.4 Device Status at Power Activation

The device switches into the following state when the power is activated.

(1)Sets the device to the state where the power was turned OFF the last time.

(2)Clears the input and output buffers.

(3)Resets the syntax analyzer, run time controller.

(4)Switches the device to the OCIS.

( 5 ) Switches the device to the OCIS.

(6)Clears all the event status enable registers, when the PSC flag is set true. Records the event after the registers are cleared.

Items related to the Power On Status Clear (PSC) flag

When the PSC flag is false, the service request enable register, standard event status enable register and other status enable register will not be affected. Moreover, when the PSC flag is true or the *PSC command is not executed. the aforementioned registers are cleared.