Avocent Cyclades-PR2000 installation manual Parameter, Example, Your Application

Models: Cyclades-PR2000

1 136
Download 136 pages 56.31 Kb
Page 28
Image 28
Global, because NAT is not being used in this

Cyclades-PR2000

STEP ONE

The first step is to determine the parameters needed to configure the Ethernet interface (ETH0). The parameters in the Network Protocol Menu (IP) are shown in Figure 4.10. Fill in the blanks for your application in the right-most column. These parameters will be entered into the router later, after all parameters have been chosen. Each parameter in this menu is explained in more detail in chapter 5 of the Installation Manual.

Menu CONFIG=>INTERFACE=>ETHERNET=>NETWORK PROTOCOL=>IP

Parameter

Example

 

Your Application

Active or Inactive

Active enables IP communication (IPX and

 

 

Transparent Bridge are not used in this

 

 

example).

 

 

Interface Unnumbered

Numbered

 

 

Primary IP Address

100.130.130.1

 

 

Subnet Mask

255.255.255.0

 

 

Secondary IP Address

0.0.0.0 for none.

 

 

IP MTU

Use the preset value, 1500.

This determines

 

 

whether or not a given IP datagram is

 

 

fragmented.

 

 

NAT

Global, because NAT is not being used in this

 

 

example.

 

 

ICMP Port

Inactive

 

 

Incoming Rule List

None, filters are not included in this example.

 

Outgoing Rule List Name

None, filters are not included in this example.

 

Proxy ARP

Inactive

 

 

IP Bridge

Inactive

 

 

FIGURE 4.10 ETHERNET NETWORK PROTOCOL MENU PARAMETERS

Chapter 4 - Step-by-Step Instructions