Cyclades-PR2000
X.25 Menu CONFIG=>INTERFACE=><LINK>=>ENCAPSULATION =>X.25
Parameter | Description |
X.121 (Local DTE) Address | Address assigned to this interface (provided by the public X.25 Network |
| Provider). Can be up to 15 digits. |
Switch Mode Active | Causes the Router to act as a switch. |
Incoming Calls Received | Applies when Switch Mode is Active. |
Over the Other X.25 Links |
|
With Unknown Destination |
|
DTE Can be Forwarded |
|
Through This Link |
|
Suppress Calling Address | Public X.25 Network: This parameter must be chosen according to the |
| guidelines given by the Public X.25 Network provider. When activated, the |
| sender's Local DTE address is not included in the Call Request Message. |
Inactivity Timeout | Time until connection is automatically terminated by the router if there is no |
| traffic. |
Configure as DTE or DCE | As mentioned above, the router can act either as the recipient of information |
| (DTE), or as the |
| routers are DTEs. |
Number of Virtual Circuits | Indicates the maximum number of virtual circuits (total of PVCs and SVCs) |
| allowed on this interface. The maximum is 64. |
Number of Permanent | Indicates the number of permanent virtual circuits that will be connected through |
Virtual Circuits | this interface. This maximum is also 64. |
Layer 3 Window Size | The layer 3 (packet) level window represents the number of sequentially |
| numbered packets that can be sent before an acknowledgement must be |
| received. This number may be negotiated if the Window Size Facility is utilized |
| (see last parameter in this table). |
Layer 2 Window Size | The layer 2 (frame) level window represents the number of sequentially |
| numbered frames that can be sent before an acknowledgement must be |
| received. The frame numbers are independent of the packet numbers. |
this table continued |
|
Chapter 8 - | 61 |