CHAPTER 5 CONFIGURATION OF THE ETHERNET INTERFACE
The PR2000 has one Ethernet
If your network uses 10Base2 (thin coaxial cable) or 10Base5 (thick coaxial cable), you will need a transceiver to convert between the different Ethernet media. A crossover cable is required for direct connection to a computer (an
The parameters in the encapsulation menu are preset at the factory and it is usually not necessary to change them. The first step in the Ethernet configuration is to choose which network protocol to use and assign values to the relevant parameters. Either IP, Transparent Bridge, or IPX (optional) must be activated. In this chapter, IP Bridges are also described. Use the information provided below to set the parameters for the Ethernet interface.
The IP Network Protocol
Some parameters are explained in detail in later chapters. At this point, the preset values provided by the operating system can be accepted and the interface will work at a basic level.
Network Protocol Menu CONFIG =>INTERFACE =>ETHERNET =>NETWORK PROTOCOL =>IP
Parameter | Description |
Active or Inactive | Activates this interface. |
Interface | Unnumbered interfaces are used for |
Unnumbered |
|
Assign IP From | Applies to Unnumbered interfaces. Applies the IP address of another router interface |
Interface | to this one. |
Primary IP Address | Applies to Numbered interfaces. Address assigned to this interface. |
Subnet Mask | Applies to Numbered interfaces. Subnet mask of the network. |
This table is continued. |
|