STEP TWO
No more parameters are necessary for the Ethernet interface. The other interface to be configured is the SWAN in slot 1. The SWAN physical media parameters are shown in Figure 4.11. Fill in the values for your application. The SWAN configuration is described in more detail in chapter 6 of the Installation Manual.
Menu CONFIG=>INTERFACE=>SWAN=>PHYSICAL
Parameter | Example | Your Application |
Mode | Synchronous. |
|
Clock Source | When the interface is connected to a |
|
| DSU/CSU, the Clock Source is External. |
|
Media for SWAN Cable | V.35 in the example because the DSU/CSU |
|
| is V.35. The type of cable is detected by the |
|
| router, so if the correct cable is connected to |
|
| the DSU/CSU the router will choose this |
|
| value as the default. |
|
FIGURE 4.11 SWAN PHYSICAL MENU PARAMETERS