Configuring Scan Delay [ DYi ]

EDIT > SETUP > PROG > DELAY

Value: 100

Range: 0–99,999

– Scan Debounce – DELAY (ms):100

Select value, press ENTER

Sets the amount of time required for the program select inputs (BCD or Binary) to remain stable before they are valid. The minimum time is 2 ms. If program select inputs are not stable for a time equal to or greater than the specified delay, the program will not be executed. Use the numeric keys to enter a value in ms. Note: See Data Valid Input Configuration for an alternate approach.

Configure Serial Communications

To use the LinStep+ serial port, several things must be done first. Use the keypad to set the auto–echo and the unit’s daisy chain address. The baud rate and other parameters have fixed values and may not be changed.

SBaud rate: 9600

SData bits: 8

SStop bits: 1

SParity: none

Action

 

 

 

Display

Comments

 

 

 

 

 

 

 

 

 

 

 

 

 

Select a sub–menu, press F1 (ECHO),

 

 

 

–RS232C SETUP–

 

 

 

 

 

F2 (UNIT#).

 

 

 

ECHO

UNIT#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuring Echo Enable

[ ECi ]

 

 

 

EDIT > SETUP > RS232 > ECHO

Value: Enabled

Range: Enabled, Disabled

Enable or disable the RS–232C ECHO feature. If ECHO is disabled, characters received by the control’s serial port will not be re–transmitted. ECHO must be enabled in daisy–chain applications.

Configuring Unit Number [ UNi ]

EDIT > SETUP > RS232 > UNIT#

Value: 1

Range: 1–99

– RS232C ECHO –

ENABLED

Select value, press ENTER

Unit Number NUMBER:1

Select value, press ENTER

Set the unit’s address. Each unit in an RS–232C serial daisy chain of multiple units must have a unique Unit Number.