Configuring Homing Mode [ HMi ]

EDIT > SETUP > HOME > MODE

Value: Switch Only

Range: Switch Only

Sets how a Go Home (GH) command will execute. The control will only search for the appropriate edge of a switch.

Configuring Home Edge [ HEi ]

EDIT > SETUP > HOME > EDGE

Value: NEGATIVE

Range: NEGATIVE, POSITIVE

Sets the home switch active on the negative edge or positive edge of the encoder index channel. Use the ← and → keys to select.

Configuring Home Switch [ HSi ]

EDIT > SETUP > HOME > SWITCH

Value: Norm Open

Range: Norm Open or Norm Closed

Selects the type of switch used for the home input. Use the ← and

keys to select.

Configuring Home Offset [ HOr ]

EDIT > SETUP > HOME > OFFSET

Value: 0.0 {Distance Units}

Range: 0.0–999,999,999.0

Sets the offset from home position for the “real” home position. After a successful homing move, the home position (the factory set home position is +0.0000) is set to the offset value. Use the numeric keys to enter a value.

This allows multiple systems to have identical programs and only change the home offset value for each machine.

–Axis One Home Mode– ←↑ Switch Only ↓→

Only one selection available. Press ← or → to select next axis.

– Axis One Home Edge –

NEGATIVE

 

Select value, press ENTER

Press ←

or → to select next axis.

–Axis One Home Switch–

Norm Open

 

Select value, press ENTER

Press ←

or → to select next axis.

–Axis One Home Offset–

0.0 in

 

Select value, press ENTER

Press ←

or → to select next axis.