Configuring Stop Decel Rate [ SRi ]

EDIT > SETUP > MISC > Stop–Rate

Value: 80 in/s2

Range: 0.0–99999.0

– Axis One Stop Decel –

80 in/s2

Enter a value, press ENTER

Set the deceleration rate used whenever a configurable stop input is activated, or when the ESC key is pressed during a move. Normally set to the fastest controllable deceleration rate possible with mechanics in your application.

Configuring Passwords [ PWaaaa,aaaa ]

EDIT > SETUP > MISC > PASWRD

Value: None

Range: N/A

Passwords allow you to restrict access to the RUN, EDIT, COPY, DEL and keypad DIP switches. Select Operator or Administrator (see Table 5-4 for description).

Enter a password, use ← → and DEL keys to edit the password.

General Password Rules:

SPasswords are 4 characters maximum. 0–9, upper and lower case letters, in any combination.

SIf no password is entered, there is no restriction.

SEntering the wrong password or pressing ESC at the password prompt will return the keypad to the standard run–time display.

SSelect EDIT > SETUP > MISC > PASWRD > CLEAR to delete all passwords.

Note: Subsequent attempts to RUN or EDIT a program do not require a password. You are prompted to: Use Last (F1) or Reset (F3). Select Use Last to run or edit another program. Select Reset to require the next user to enter a password.

– Password Setup –

OPRATR ADMIN CLEAR

Select a value, press ENTER

 

 

Table 5-4

Password Type

Description

Gives access to these menus

OPRATR

Operator only

RUN, EDIT, COPY, DEL

ADMIN

Administrator only

RUN, EDIT, COPY, DEL

CLEAR

Clears Passwords

 

5-18 Setup

MN1854

Page 55