CL

CT

DA

Not Implemented

syntax –

Value:

Units:

Range:

Not Implemented

syntax –

Value:

Units:

Range:

Distance Absolute

syntax – DA± r

Value:

N/A

 

Units:

set in EDIT > SETUP > MECH > DIST

 

Range:

Unit scaling dependent

 

Sets the next move position, referenced from absolute zero. The absolute zero position is established after a Go Home move (GH) and/or with the Set Position (SP) command. Absolute positioning is typically used to move between a number of known locations, or if the physical work area is restricted.

Incremental (DI) and absolute moves may be mixed; the control keeps track of the absolute position.

Example:

AC2 DE.5 VE12 DA3 GO DA3 GO DA3 GO

Moves to absolute position 3 units. Moves once to absolute position 3 units.

6-2 Keypad Programming

MN1854

Page 57
Image 57
Baldor mn1854 manual Keypad Programming MN1854, Value Units Range, Example, AC2 DE.5 VE12 DA3 GO DA3 GO DA3 GO