Permanent Store Menu

Block Title

Parameter

Description

 

 

 

Permanent Store

Save Parameters

Saves all parameter values and overwrites previously saved values.

 

 

 

 

Power on

Restores all parameter values to the values that were last saved (last power up cycle).

 

Parameters

All parameter values changes since last power up are overwritten. Display blinks

 

 

twice to confirm reset is complete.

 

 

 

 

Default Parameters

Restores all parameter values to the factory settings. All parameter values are

 

 

overwritten. Display blinks twice to confirm reset is complete.

 

 

 

Password Menu

Block Title

 

Parameter

 

Description

 

 

 

 

 

Password

 

Enter Password

 

If a password is set, it prevents unauthorized users from changing any parameter

 

 

 

 

values. Value can be 0 to 255 (0=no password). If the correct password is entered,

 

 

 

 

all parameters are unlocked. Parameter 5.

 

 

 

 

 

 

 

Change Password

 

If the parameters are unlocked, a new password can be set using this option. Value can

 

 

 

 

be 0 to 255 (0=no password). Parameter 5.

 

 

 

 

Note: Remember your password. Removing power etc. will not clear the

 

 

 

 

password. When a password is set, use Enter Password to unlock

 

 

 

 

the parameters.

 

 

 

 

 

Inputs Menu

 

 

 

 

Block Title

 

Parameter

 

Description

 

 

 

 

 

 

 

Inputs

 

Digital i/p1

 

Input 1 is available at J10, terminals S1 (hot) and S0 (neutral). May be set as follows:

 

 

 

 

Map to – Value can be parameter 0 – 112. Parameter 65.

 

 

 

 

Bit number – Press “Optimise” to shift one position to the left. Press “” to change that

 

 

 

 

character to a logic 1. Press “” to change that character to a logic 0.

 

 

 

 

The value is stored in Parameter 66.

 

 

 

 

Polarity – Value of each of the 8 I/O bits can be Positive or Inverse Logic. The value is

 

 

 

 

stored in Parameter 54.

 

 

 

 

 

 

 

Digital i/p2

 

Reserved for future use.

 

 

 

 

 

 

 

Digital i/p3

 

Reserved for future use.

 

 

 

 

 

 

 

Temperature i/p

 

Reserved for future use.

 

 

 

 

 

 

 

4–20ma i/p

 

Reserved for future use.

 

 

 

 

 

 

 

DC i/p

 

Reserved for future use.

 

 

 

 

 

MN850

Parameter Index 4-5

Page 32
Image 32