Baldor Baldor manual Applications MN850

Models: MN850 Baldor

1 70
Download 70 pages 3.46 Kb
Page 59
Image 59

 

 

 

 

Read Only Parameter Values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

P#

Parameter

 

Adjustable Range

 

Factory

User Setting

 

 

 

 

 

 

 

Parameters

P36

% Overload (status only)

 

0–100% (100%=Tripped)

0%

 

 

 

 

 

 

 

 

 

 

P37

Chassis Temperature

 

0–255

0

 

 

 

 

 

 

 

 

 

 

 

P38

Pot1

 

0–255

0

 

 

 

 

 

 

 

 

 

 

 

P39

Pot2

 

0–255

0

 

 

 

 

 

 

 

 

 

 

 

P40

Pot3

 

0–1

0

 

 

 

 

 

 

 

 

 

 

P41

DC I/P

 

0–12

0VDC

 

 

 

 

 

 

 

 

 

 

P42

Thermistor

 

0–255

0

 

 

 

 

 

 

 

 

 

 

P43

4–20mA I/P

 

0–20.4

0mA

 

 

 

 

 

 

 

 

 

P44

TEMP Trip Level

 

20–255

30

 

 

 

 

 

 

 

 

 

 

P45

4–20mA Map

 

0–125

0

(parameter #)

 

 

 

 

 

 

 

 

 

P46

4–20mA Set Level

 

0.08–20.32

10.24mA

 

 

 

 

 

 

 

 

 

 

P47

DC Input Map

 

0–125

0

(parameter #)

 

 

 

 

 

 

 

 

 

P48

Set Level DC I/P

 

0.03922–9.960784

5.019608 VDC

 

 

 

 

 

 

 

 

 

P49

Map DAC O/P 1

 

0–125

26 (parameter #)

 

 

 

 

 

 

 

 

 

P50

Map DAC O/P 2

 

0–125

22 (parameter #)

 

 

 

 

 

 

 

 

 

P51

User Flags 1

 

0–255

142 (Bit 10001110)

 

 

 

 

 

 

 

 

 

 

P52

User Flags 2

 

0–255

0

(Bit 00000000)

 

 

 

 

 

 

 

 

 

P53

User Flags 3

 

0–255

19 (Bit 00010011)

 

 

 

 

 

 

 

 

 

P54

I/O Polarity

 

0–255

127 (Bit 01111111)

 

 

 

 

 

 

 

 

 

 

P55

MAP LED

 

0–255

9

(x Ie)

 

 

 

 

 

 

 

 

 

 

P56

LED MASK

 

0–255

1

(x Ie)

 

 

 

 

 

 

 

 

 

P57

Map K1 To (Parameter)

 

0–125

52 (Parameter #)

 

 

 

 

 

 

 

 

 

P58

K1 Bit Mask (P57 bit selected for K1)

 

0–255

32 (bit 00100000)

 

 

 

 

 

 

 

 

 

 

P59

Map K2 To (Parameter)

 

0–125

8

(Parameter #)

 

 

 

 

 

 

 

 

 

 

P60

K2 Bit Mask (P59 bit selected for K2)

 

0–128

8

(bit 00001000)

 

 

 

 

 

 

 

 

 

 

P61

Map K3 To (Parameter)

 

0–125

9

(Parameter #)

 

 

 

 

 

 

 

 

 

 

P62

K3 Bit Mask (P61 bit selected for K3)

 

0.1–3

1

(bit 00000001)

 

 

 

 

 

 

 

 

 

 

P63

Map K4 To (Parameter)

 

0–125

9

(Parameter #)

 

 

 

 

 

 

 

 

 

 

P64

K4 Bit Mask (P63 bit selected for K4)

 

0–3

2

(bit 00000010)

 

 

 

 

 

 

 

 

 

P65

Map I/P1 To (Parameter)

 

0–125

52 (Parameter #)

 

 

 

 

 

 

 

 

 

P66

I/P1 Bit Mask (P65 bit selected for I/P1)

 

0–128

16 (bit 00010000)

 

 

 

 

 

 

 

 

 

 

P67

Map I/P2 To (Parameter)

 

0–125

0

(Parameter #)

 

 

 

 

 

 

 

 

 

 

P68

I/P2 Bit Mask (P67 bit selected for I/P2)

 

0–128

0

(bit 00000000)

 

 

 

 

 

 

 

 

 

 

P69

Map I/P3 To (Parameter)

 

0–125

0

(Parameter #)

 

 

 

 

 

 

 

 

 

 

P70

I/P3 Bit Mask (P69 bit selected for I/P3)

 

0–128

0

(bit 00000000)

 

 

 

 

 

 

 

 

Advanced Current

P71

Contactor Delay (after start command)

 

20–800milli seconds

160 milli seconds

 

 

 

 

 

 

 

 

 

 

P72

Trip Sensitivity (1=fastest trip)

 

1–15 (Status Code)

1

 

 

 

 

 

 

 

 

 

 

 

P73

Last Trip (Most Recent Trip)

 

1–16 (Status Code)

0

 

 

 

 

 

 

 

 

 

 

 

B-2 Applications