Section 1

General Information

 

 

 

 

Read Only Parameter Values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

P#

Parameter

 

 

Adjustable Range

 

Factory

User Setting

 

 

 

 

 

 

 

 

 

Parameters

P74

2nd Last Trip

 

 

1–16 (Status Code)

0

 

 

 

 

 

 

 

 

 

 

 

 

P75

3rd Last Trip

 

 

1–16 (Status Code)

0

 

 

 

 

 

 

 

 

 

 

 

 

P76

4th Last Trip

 

 

1–16 (Status Code)

0

 

 

 

 

 

 

 

 

 

 

 

 

P77

5th Last Trip (Oldest trip)

 

 

1–16 (Status Code)

0

 

 

 

 

 

 

 

 

 

 

 

P78

Protection Mode 2

 

 

0–192

192 (Full + Optimize)

 

 

 

 

 

 

 

 

 

 

P79

Start Pedestal 2

 

 

10–60%

50 (% of line volts)

 

 

 

 

 

 

 

 

 

 

P80

Start Time 2

 

 

1–255 seconds

5 seconds

 

 

 

 

 

 

 

 

 

 

P81

Kick Pedestal 2

 

 

60–90%

75 (% of line volts)

 

 

 

 

 

 

 

 

 

 

P82

Kick Time 2

 

 

10–40 seconds

25 seconds

 

 

 

 

 

 

 

 

 

 

P83

Dwell 2

 

 

1–255 seconds

5 seconds

 

 

 

 

 

 

 

 

 

 

P84

Stop Pedestal 2

 

 

10–60 seconds

10 seconds

 

 

 

 

 

 

 

 

 

 

P85

Stop Time 2

 

 

0–255 seconds

0 seconds

 

 

 

 

 

 

 

 

 

 

 

P86

Auto Config 2

 

 

0–255

6

(Bit 00000110)

 

 

 

 

 

 

 

 

 

 

P87

Under Current 2

 

 

0–1 (x Ie) Amps

0.125 x Ie Amps

 

 

 

 

 

 

 

 

 

 

P88

Under Current Time 2

 

 

5–255 seconds

50 seconds

 

 

 

 

 

 

 

 

 

 

P89

Current Limit 2

 

 

0–8 (x Ie) Amps

4 x Ie Amps

 

 

 

 

 

 

 

 

 

 

P90

Current Limit Time 2

 

 

5–255 seconds

15 seconds

 

 

 

 

 

 

 

 

 

 

P91

Shearpin 2

 

 

1–5 (x Ie) Amps

3 x Ie Amps

 

 

 

 

 

 

 

 

 

 

P92

Shearpin Time 2

 

 

5–255 cycles

50 cycles

 

 

 

 

 

 

 

 

 

 

P93

Overload Level 2

 

 

0.5–2 (x Ie) Amps

1.09375 x Ie Amps

 

 

 

 

 

 

 

 

 

 

P94

Overload Delay 2

 

 

10–140 seconds

140 seconds

 

 

 

 

 

 

 

 

 

 

P95

User Flags 1 (for 2nd param set)

 

 

0–255

134 (Bit 10000110)

 

 

 

 

 

 

 

 

 

 

P96

User Flags 2 (for 2nd param set)

 

 

0–255

64 (Bit 01000000)

 

 

 

 

 

 

 

 

 

 

 

P97

Flag 1 I/P Source Address

 

 

0–125

0

(Parameter #)

 

 

 

 

 

 

 

 

 

 

 

P98

Flag 1 I/P Source Mask

 

 

0–128

0

(bit 00000000)

 

 

 

 

 

 

 

 

 

 

 

P99

Flag 1 O/P Destination Address

 

 

0–125

0

(Parameter #)

 

 

 

 

 

 

 

 

 

 

 

P100

Flag 1 O/P Destination Mask

 

 

0–255

0

(bit 00000000)

 

 

 

 

 

 

 

 

 

 

 

P101

Flag 2 I/P Source Address

 

 

0–125

0

(Parameter #)

 

 

 

 

 

 

 

 

 

 

 

P102

Flag 2 I/P Source Mask

 

 

0–20

0

(bit 00000000)

 

 

 

 

 

 

 

 

 

 

 

P103

Flag 2 O/P Destination Address

 

 

0–125

0

(Parameter #)

 

 

 

 

 

 

 

 

 

 

 

P104

Flag 2 O/P Destination Mask

 

 

0–11

0

(bit 00000000)

 

 

 

 

 

 

 

 

 

 

P105

Loop Input

 

 

0–125

41 (Parameter #)

 

 

 

 

 

 

 

 

 

 

P106

Loop Feedback

 

 

0–125

26 (Parameter #)

 

 

 

 

 

 

 

 

 

 

P107

Error Gain

 

 

1–255

37

 

 

 

 

 

 

 

 

 

 

 

P108

Error Divisor

 

 

1–255

7

 

 

 

 

 

 

 

 

 

 

 

P109

Max Slope

 

 

0–50

10

 

 

 

 

 

 

 

 

 

 

P110

Guard Gap

 

 

0–150

10

 

 

 

 

 

 

 

 

 

 

MN850

Applications B-3

Page 60
Image 60
Baldor Baldor manual MN850 Applications B-3