Section 1
General Information
Optional Remote Keypad Installation The keypad may be remotely mounted using optional Baldor keypad extension cable. Keypad assembly (white -
Tools Required:
• Center punch, tap handle, screwdrivers (Phillips and straight) and crescent wrench.
•
•
• RTV sealant.
• (4)
• Extended
• Remote keypad mounting template. A tear out copy is provided at the end of this manual for your convenience. (Photo copy or tear out.)
Mounting Instruction: | For tapped mounting holes | |
| 1. | Locate a flat 4″ wide x 5.5″ minimum high mounting surface. Material should |
|
| be sufficient thickness (14 gauge minimum). |
| 2. | Place the template on the mounting surface or mark the holes as shown. |
| 3. | Accurately center punch the 4 mounting holes (marked A) and the large |
|
| knockout (marked B). |
| 4. | Drill four #29 mounting holes (A). Thread each hole using an |
| 5. | Locate the |
|
| instructions. |
| 6. | Debur knockout and mounting holes making sure the panel stays clean and flat. |
| 7. | Apply RTV to the 4 holes marked (A). |
| 8. | Assemble the keypad to the panel. Use |
| 9. | From the inside of the panel, apply RTV over each of the four mounting screws |
|
| and nuts. Cover a 3/4″ area around each screw while making sure to completely |
|
| encapsulate the nut and washer. |
Mounting Instructions: | For clearance mounting holes | |
| 1. | Locate a flat 4″ wide x 5.5″ minimum high mounting surface. Material should |
|
| be sufficient thickness (14 gauge minimum). |
| 2. | Place the template on the mounting surface or mark the holes as shown on the |
|
| template. |
| 3. | Accurately center punch the 4 mounting holes (marked A) and the large |
|
| knockout (marked B). |
| 4. | Drill four #19 clearance holes (A). |
| 5. | Locate the |
|
| instructions. |
| 6. | Debur knockout and mounting holes making sure the panel stays clean and flat. |
| 7. | Apply RTV to the 4 holes marked (A). |
| 8. | Assemble the keypad to the panel. Use |
| 9. | From the inside of the panel, apply RTV over each of the four mounting screws |
|
| and nuts. Cover a 3/4″ area around each screw while making sure to completely |
encapsulate the nut and washer.
MN850 | Installation |