2-4 Configuration via Serial Interface

 

Installation

 

To configure the RIPM via serial interface, a null modem cable is required (provided). Connect the null modem cable to the “Serial 01” port on the RIPM and the other end to the serial port on the computer. The serial interface needs to be adjusted with the parameters as shown below:

Parameter

Value

 

 

Bits/second

115200

 

 

Data bits

8

 

 

Parity

no

 

 

Stop bits

1

 

 

Flow control

none

 

 

Use a terminal software program (e.g., HyperTerminal) to connect to the RIPM. Reset the RIPM and immediately press the “ESC” key. You will see a “=>” prompt. Enter the command “config” and press the “ENTER” key. You will be asked to adjust the IP auto configuration, the IP address, the net mask, and the default gateway. Pressing the “ENTER” key without entering values does not change settings. The gateway value has to be set to “0.0.0.0” (for no gateway) or any other value for the IP address of the gateway. After the confirmation, the RIPM performs a reset using the new values as set before.