Table 92: Modem IIIa2 Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Event

Device/Mode

Display

 

 

Explanation

Refer to Section

 

 

 

 

 

 

 

 

 

C.1 Zonex and

 

 

 

 

 

 

 

 

 

Comex

 

 

 

 

 

 

 

 

 

Translation on

 

 

 

 

 

 

 

 

 

page 137.

 

 

 

 

 

 

 

 

 

 

 

 

573.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

The RELAY specified

 

 

 

 

 

(by USER)

 

+++ ACC aaaa

 

BY USER

in the second line of

 

 

 

 

 

 

 

+++ ACC aaaa

ID=iii RELAY#=rrr

the report was reset.

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD18t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNidiiiROrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

574.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

 

 

 

 

 

 

(relay <255,

 

+++ACC aaaa

 

BY USER

 

 

 

 

 

 

user > 254)

 

+++ACC aaaa

ID=iiii RELAY#=rrr

 

 

 

 

 

 

(by USER)

D6500 Mode:

h1rrlssssssaaaasNsD18t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNidiiiiROrrr]

 

 

 

 

 

575.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

 

 

 

 

 

 

(relay > 254)

 

+++ACC aaaa

 

BY SKED

 

 

 

 

 

 

(by SKED)

 

+++ACC aaaa

RELAY#=rrrr SKED=kkk

 

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD20t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNaikkkROrrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

576.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

 

 

 

 

 

 

(relay > 254)

 

+++ACC aaaa

 

BY PROGRAMMER

 

 

 

 

 

 

(by

 

+++ACC aaaa

RELAY#=rrrr SDI=ddd

 

 

 

 

 

 

Programmer)

D6500 Mode:

h1rrlssssssaaaasNsD22t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNpidddROrrrr]

 

 

 

 

 

577.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

 

 

 

 

 

 

(relay > 254)

 

+++ACC aaaa

 

BY REMOTE

 

 

 

 

 

 

(by RAM)

 

+++ACC aaaa

 

RELAY#=rrrr

 

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD24t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNROrrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

578.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

 

 

 

 

 

 

(relay >254,

 

+++ACC aaaa

 

BY USER

 

 

 

 

 

 

user < 255)

 

+++ACC aaaa

ID=iii RELAY#=rrrr

 

 

 

 

 

 

(by USER)

D6500 Mode:

h1rrlssssssaaaasNsD18t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNidiiiROrrrr]

 

 

 

 

 

579.

Relay Reset

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

 

 

 

 

 

 

(relay >254,

 

+++ACC aaaa

 

BY USER

 

 

 

 

 

 

user > 254)

 

+++ACC aaaa

ID=iiii RELAY#=rrrr

 

 

 

 

 

 

(by USER)

D6500 Mode:

h1rrlssssssaaaasNsD18t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNidiiiiROrrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580.

Relay Reset by

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

The RELAY specified

7,

 

 

 

 

Sked

 

+++ ACC aaaa

RELAY#=rrr SKED=kk

in the second line of

D9112

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD20t

 

the report was reset.

 

 

 

 

SIA Mode:

<header>[#aaaaNaikkROrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581.

Relay Reset by

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY RESET

The RELAY specified

1,

 

 

 

 

User

 

+++ ACC aaaa

ID=iii RELAY#=rrr

in the second line of

7,

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD18t

 

the report was reset.

 

 

 

 

 

SIA Mode:

<header>[#aaaaNidiiiROrrr]

 

D9112

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

582.

Relay Set

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY SET

The RELAY specified

 

 

 

 

 

(by

 

+++ ACC aaaa

 

BY PROGRAMMER

in the second line of

 

 

 

 

 

Programmer)

 

+++ ACC aaaa

RELAY#=rrr SDI=ddd

the report was set.

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD21t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNpidddRCrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

583.

Relay Set

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY SET

The RELAY specified

 

 

 

 

 

(by RAM)

 

+++ ACC aaaa

 

BY REMOTE

in the second line of

 

 

 

 

 

 

 

+++ ACC aaaa

 

RELAY#=rrr

the report was set.

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD23t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNRCrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

584.

Relay Set

Printer:

dd/dd tt:tt Lxx ACC aaaa

RELAY SET

The RELAY specified

 

 

 

 

 

(by SKED)

 

+++ ACC aaaa

 

BY SKED

in the second line of

 

 

 

 

 

 

 

+++ ACC aaaa

RELAY#=rrr SKED=kk

the report was set.

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasNsD19t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNaikkRCrrr]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 