Bosch Appliances D6600, D6100 manual 3.2.3Ademco 4-1Express Message Type b, Message sent to printer

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 30
Image 30
3.2.3Ademco 4-1 Express (Message Type b)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

3.2.3Ademco 4-1 Express (Message Type b)

4-1 Express Example

SIA Mode Description

<LF><CRC><b><sequence#><receiver#><line#>[#aaaaX]<CR>

Table 41: Ademco 4-1 Express (Message Type b) Byte Description

 

 

 

 

 

 

Title

 

Description

 

 

 

 

 

 

LF

 

 

Standard line feed character.

 

CRC

 

Cyclical redundancy check number.

 

Message Type

 

b

 

sequence#

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

receiver#

 

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for the

 

 

 

 

D6600/D6100.

 

line#

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

 

(Line/Group #)

 

to 99. The receiver uses Line 0 (zero) for internal messages.

 

 

 

 

 

account#

 

 

The communicator's account number has four digits.

 

X

 

Zone number

Figure 9: Message sent to printer

mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X

For lines that are grouped, Gxx appears instead of Lxx.

Table 42: Ademco 4-1 Express (Message

 

Type b) Printer Output

 

 

 

 

 

 

Characters

 

Description

 

 

 

E41

 

Ademco 4-1 Express format.

Lxx:

 

Line number.

Gxx

 

Grouped line numbers.

30

Bosch Security Systems, Inc. 1/07 4998122703-01

Page 30
Image 30
Bosch Appliances D6600, D6100 manual 3.2.3Ademco 4-1Express Message Type b, Message sent to printer, Type b Printer Output