Bosch Appliances D6600, D6100 manual Bosch Security Systems, Inc. | 1/07

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 56
Image 56
Manual background

Conettix D6600/D6100 Computer Interface Manual Appendix A: Contact ID Event Code Classifications

Table 90: Event Codes (continued)

 

 

 

 

#

Event Type

Zone

 

 

 

 

 

Open/Close:

 

464

Auto Arm Time

Status-Auto Arm Time Ext.-

 

 

Extended

User # (Restore not

 

 

 

applicable)

 

 

 

465

Panic Alarm Reset

Status-PA Reset (Restore not

 

 

 

applicable)

 

Remote Access:

 

411

Callback

Remote-Callback Requested

 

 

Requested

(Restore not applicable)

412

Success-

Remote-Successful Access

 

 

Download/access

(Restore not applicable)

 

 

 

413

Unsuccessful

Remote-Unsuccessful Access

 

 

Access

(Restore not applicable)

414

System Shutdown

Remote-System Shutdown

415

Dialer Shutdown

Remote-Dialer Shutdown

416

Successful Upload

Remote-Successful Upload

 

 

 

(Restore not applicable)

Access Control:

 

421

Access Denied

Access-Access Denied-User

 

 

 

# (Restore not applicable)

 

 

 

422

Access Report by

Access-Access Gained-User

 

 

User

# (Restore not applicable)

423

Forced Access

Panic-Forced Access-#

424

Egress Denied

Access-Egress Denied

 

 

 

(Restore not applicable)

425

Egress Granted

Access-Egress Granted

 

 

 

(Restore not applicable)

426

Access Door

Access-Door Propped Open-

 

 

Propped Open

#

427

Access Point DSM

Access-ACS Point DSM Trbl.-

 

 

Trouble

#

 

 

 

428

Access Point RTE

Access-ACS Point RTE Trbl.-

 

 

Trouble

#

429

Access Program

Access-ACS Prog. Entry-User

 

 

Mode Entry

# (Restore not applicable)

 

 

 

430

Access Program

Access-ACS Prog. Exit-User

 

 

Mode Exit

# (Restore not applicable)

431

Access Threat

Access-ACS Threat Level

 

 

Level Change

Chg.

 

 

 

432

Access

Access-ACS Relay/Trig. Fail-

 

 

Relay/Trigger Fail

#

433

Access RTE Shunt

Access-ACS RTE Shunt-#

434

Access DSM Shunt

Access-ACS DSM Shunt-#

 

 

 

System Disables:

 

501

Access Reader

Disable-Access Rdr. Disable-

 

 

Disable

#

Table 90: Event Codes (continued)

 

 

 

#

Event Type

Zone

 

 

 

Sounder/Relay Disables:

 

520

Sounder/Relay

Disable-Sounder/Relay-#

 

Disable

 

521

Bell 1 Disable

Disable-Bell/Siren #1

522

Bell 2 Disable

Disable-Bell/Siren #2

 

 

 

523

Alarm Relay

Disable-Alarm Relay

 

Disable

 

524

Trouble Relay

Disable-Trouble Relay

 

Disable

 

 

 

 

525

Reversing Relay

Disable-Reversing Relay

 

Disable

 

526

Notification

Disable-Notification Appl. Ckt

 

Appliance Ckt #3

#3

 

 

 

527

Notification

Disable-Notification Appl. Ckt

 

Appliance Ckt #4

#4

System Peripheral Disables:

 

531

Module Added

Super.-Module Added

 

 

(Restore not applicable)

532

Module Removed

Super.-Module Removed

 

 

(Restore not applicable)

 

 

 

Communication Disables:

 

551

Dialer Disabled

Disable-Dialer Disable

552

Radio Xmitter

Disable-Radio Disable

 

Disabled

 

553

Remote

Disable-Rem. Up/Download

 

Upload/Download

Disable

Bypasses:

 

570

Zone/Sensor

Bypass-Zone Bypass-#

 

Bypass

 

 

 

 

571

Fire Bypass

Bypass-Fire Bypass-#

 

 

 

572

24 Hour Zone

Bypass-24 Hour Bypass-#

 

Bypass

 

573

Burg. Bypass

Bypass-Burg. Bypass-#

574

Group Bypass

Bypass-Group Bypass-User #

 

 

 

575

Swinger Bypass

Bypass-Swinger Bypass-#

 

 

 

576

Access Zone Shunt

Access-ACS Zone Shunt-#

 

 

 

577

Access Point

Access-ACS Point Bypass-#

 

Bypass

 

56

Bosch Security Systems, Inc. 1/07 4998122703-01

Page 56
Image 56
Bosch Appliances D6600, D6100 manual Bosch Security Systems, Inc. | 1/07