Bosch Appliances D6100, D6600 manual Optional Silent Knight FSK1 Message Type m

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 45
Image 45
Optional Silent Knight FSK1 (Message Type m)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

Optional Silent Knight FSK1 (Message Type m)

If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to1, the following output is used.

Silent Knight FSK1 Example

SIA Mode Description

<LF><CRC><m><sequence#><receiver#><line#>[#aaaaZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ]<

CR>

 

 

Table 76: Optional Silent Knight FSK1 (Message Type m) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

 

 

 

Description

 

 

 

 

 

 

LF

 

 

 

Standard line feed character.

 

 

 

 

 

CRC

 

 

 

Cyclical redundancy check number.

 

 

 

 

 

Message Type

 

 

 

m

 

 

 

 

 

 

sequence#

 

 

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

 

receiver#

 

 

 

The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.

 

 

 

line#

 

 

 

The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to

 

 

 

(Line/Group #)

 

 

 

99. The receiver uses Line 0 (zero) for internal messages.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

account #

 

 

 

The communicator's account number has four digits.

 

 

 

 

ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”Z

Up to eight reports. One report has two digits. The quote (“) is the separate character.

 

 

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 77: Silent Knight FSK1 Optional Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Report Code

Description

To Automation

 

Note

 

 

 

 

 

 

 

 

2 5 16 = 0(EEZZ)

2 5 16 = 1(ZZ)

 

 

 

 

00

Alarm Panic

PAss

00

 

 

 

 

01 to 08

Alarm 01 to 08

sA0x

01 to 08

x = 1 to 8

 

 

09

Holdup

Hass

09

 

 

 

 

10 to 19

Alarm 10 to 19

sA1x

10 to 19

x = 0 to 9

 

 

 

20 to 29

Alarm Restore 10 to 19

sH1x

20 to 29

x = 0 to 9

 

 

30

Test Code

sXss

30

 

 

 

31

Trouble Line 1

LT01

31

 

 

 

32

Trouble Line 2

LT02

32

 

 

 

 

 

 

 

 

 

 

33

Expand Trouble

ETss

33

 

 

 

34

Forced Access

DFss

34

 

 

 

35

Restore Line 1

LR01

35

 

 

 

36

Restore Line 2

LR02

36

 

 

 

 

 

 

 

 

 

 

37

Expand Restore

ERss

37

 

 

 

38

Cancel Code

OCss

38

 

 

 

39

Data Lost

RTss

39

 

 

 

40

Closing

CL00

40

 

 

 

 

 

 

 

 

 

 

 

 

41 to 49

Closing 01 to 09

CL0x

41 to 49

x = 1 to 9

 

 

 

50 to 59

Bypass 10 to 19

sB1x

50 to 59

x = 0 to 9

 

 

60

Trouble AC

ATss

60

 

 

 

 

61 to 68

Trouble 01 to 08

sT0x

61 to 68

x = 1 to 8

 

 

69

Trouble BAT

YTss

69

 

 

 

70

Restore AC

ARss

70

 

 

 

 

71 to 78

Restore 01 to 08

sRss

71 to 78

 

 

 

79

Restore BAT

YRss

79

 

 

 

80

Access

DS00

80

 

 

 

 

81 to 89

Access 01 to 09

DG0x

80 to 89

x = 1 to 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 1/07 4998122703-01

 