Bosch Appliances D6100 Modem IIIa2 Messages continued, Bosch Security Systems, Inc. 1/07, Comex

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 89
Image 89
Manual background

Conettix D6600/D6100 Computer Interface Manual Appendix C: Modem IIIa2 Messages

 

Table 92: Modem IIIa2 Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Event

Device/Mode

Display

 

 

Explanation

Refer to Section

 

 

 

 

 

 

 

 

 

C.1 Zonex and

 

 

 

 

 

 

 

 

 

Comex

 

 

 

 

 

 

 

 

 

Translation on

 

 

 

 

 

 

 

 

 

page 137.

 

 

338.

Fire Trouble

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE TROUBLE

 

 

 

 

 

(point < 255)

 

+++ACC aaaa

WATER FLOW DETECTOR

 

 

 

 

 

 

 

+++ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaGsspppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaSTppp]

 

 

 

 

 

339.

Fire Trouble

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE TROUBLE

 

 

 

 

 

(point < 254)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaGsppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaaFTpppp]

 

 

 

 

 

340.

Fire Trouble

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE TROUBLE

 

 

 

 

 

(with Ground

 

+++ACC aaaa

 

GROUND FAULT

 

 

 

 

 

Fault)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

(point > 254)

D6500 Mode:

h1rrlssssssaaaaGsppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaaFTpppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

341.

Fire Trouble

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE TROUBLE

 

 

 

 

 

(point > 254)

 

+++ACC aaaa

SMOKE DETECTOR

 

 

 

 

 

 

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaGsppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaaFTpppp]

 

 

 

 

 

342.

Fire Trouble

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE TROUBLE

 

 

 

 

 

(point > 254)

 

+++ACC aaaa

HIGH TEMPERATURE DETECTOR

 

 

 

 

 

 

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaGsppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaaKTpppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

343.

Fire Trouble

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE TROUBLE

 

 

 

 

 

(point > 254)

 

+++ACC aaaa

WATER FLOW DETECTOR

 

 

 

 

 

 

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaGsppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaaSTpppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

344.

Fire Walk End

Printer:

dd/dd tt:tt

Lxx ACC aaaa

FIRE WALK END

Fire Walk Test ended.

 

 

 

 

 

 

+++ ACC aaaa

 

AREA=a

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasRsssFt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaFK]

 

 

 

 

 

345.

Fire Walk End

Printer:

dd/dd tt:tt

Lxx ACC aaa

RESTORAL ZN F

 

D9112

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasRsssFt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNURF]

 

 

 

 

 

346.

Fire Walk Start

Printer:

dd/dd tt:tt

Lxx ACC aaaa FIRE WALK START

Fire Walk Test begun.

D9112

 

 

 

 

 

+++ ACC aaaa

AREA=a ID=iii

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNria/idiiiFI]

 

 

 

 

347.

Fire Walk Start

Printer:

dd/dd tt:tt

Lxx ACC aaa

TROUBLE ZN F

Abnormal RAM

D9112

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

session termination or

 

 

 

 

 

SIA Mode:

<header>[#aaaaNBTF]

 

beginning of the

 

 

 

 

 

 

 

 

 

Command 58 Fire

 

 

 

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

 

348.

Fire Walk Start

Printer:

dd/dd tt:tt

Lxx ACC aaaa FIRE WALK START

Fire Walk Test begun.

 

 

 

 

 

 

+++ ACC aaaa

AREA=a ID=iii

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNria/idiiiFI]

 

 

 

 

 

 

 

 

 

 

 

 

 

349.

Fire Walk Start

Printer:

dd/dd tt:tt

Lxx ACC aaaa FIRE WALK START

 

 

 

 

 

(no user)

 

+++ACC aaaa

 

AREA=a

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaFI]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350.

Fire Walk Start

Printer:

dd/dd tt:tt

Lxx ACC aaaa FIRE WALK START

 

 

 

 

 

(users > 254)

 

+++ACC aaaa

AREA=aa ID=iiii

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaa/idiiiiFI]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 1/07 4998122703-01

 

 

89

Page 89
Image 89
Bosch Appliances D6100, D6600 manual Modem IIIa2 Messages continued, Bosch Security Systems, Inc. 1/07, C.1 Zonex and, Comex