3.1.15 Robofon (Message Type j)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

Table 16: Link Test (Message Type 1) Byte Description

#

Title

Description

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Number

Line number as zero for link test.

6-15

Spaces

Eleven spaces.

16-17

Event Code

Event code is @ for link test.

18-21

Spaces

Four spaces.

22

Trailer Character

Typically, this is HEX 14.

3.1.15 Robofon (Message Type j)

Robofon Example

D6500 Byte Description

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

h j r r l s s s s a a a a a a E E s s s s t

Table 17: Robofon (Message Type j) Byte Description

#

Title

Description

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

j

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-9

 

Spaces

Four spaces.

10-15

 

Account Number

Six digit account number.

 

16-17

 

EE

 

Event code.

18-21

 

Spaces

Four spaces.

 

 

 

 

22

 

Trailer Character

Typically, this is HEX 14.