C.1 Zonex and Comex Translation

Conettix D6600/D6100 Computer Interface Manual Appendix C: Modem IIIa2 Messages

C.1 Zonex and Comex Translation

These numbered items correspond to the number in the last column in Table 92 starting on page 61.

1.The D7112/D9112 verifies the user identification and point data formats and sends them to the automation system. If the control panel requests a translation, the D6600/D6100 converts point data to Zonex format and user IDs to Comex format. If there is no request for translation, points and IDs are sent to the automation PC and print on the connected printer with no conversion. Table 94 shows the translation of User IDs and Table 93 shows the translation of point data.

Table 93: Point to Zonex Translation

 

 

Point

ZONEX

 

 

001-008

100-800

009-024

101-116

 

 

025-040

201-216

041-056

301-316

 

 

057-072

401-416

073-088

501-516

 

 

089-104

601-616

105-120

701-716

 

 

121-136

801-816

137-152

117-132

 

 

153-168

217-232

169-184

317-332

 

 

185-200

417-432

201-216

517-532

 

 

217-232

617-632

233-247

717-731

 

 

Table 94: User ID to Comex Translation

 

 

ID

COMEX

 

 

0

0

1-5

001-005

 

 

0-13

601-608

14-21

701-708

 

 

22-29

801-808

30-37

B01-B08

 

 

38-45

C01-C08

46-53

D01-D08

 

 

54-61

E01-E08

62-69

F01-F08

 

 

70-249

000

 

 

2.A D7112 using the Modem II format can transmit these messages.

3.Not used.

4.When the D7112 is transmitting a test report in Modem II format, the area number is sent to the automation system if the output format is in SIA communications mode.

Example 1: Log Threshold Since Last Call

<header>[#aaaaOriaJL]

5.When transmitted by a D7112, the identification number, if any, also prints. Refer to Forced Point in the D9112B Program Entry Guide

(P/N: 74-06145-000-D).

6.Not entering a phone number turns off these messages for the event class. All messages in this class exist in a unique event class.

7.For these events, the area denotes the location of the keypad used to initiate the event (see Sensor Reset).

8.BFSK Format: For the D9112, unless otherwise specified, the zone digit “z” uses the “BFSK Zone Code” as a base for a given point. This code is programmed in the control panel by point. The zone digit “i” indicates the most significant digit of the user ID.

9.For the D7112, unless otherwise specified, Table 95 is the basis for the zone digit “z” and ID translation; however, actual IDs only go up to 25.

Table 95: Reported Zone/ID to Actual Point/ID

Reported Zone/ID

 

1

2

3

4

5

6

7

8

Actual

1

2

3

4

5

6

7

8

Point/ID

 

 

 

 

 

 

 

 

 

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

 

 

 

 

 

 

 

 

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

10.This message reports from a D7112 RF point. The internal or external printer prints the label “RF POINT=” instead of “POINT=” in the second line (Example 2).

Example 2: Label RF Point

dd/dd tt:tt ql ACC aaaa FIRE ALARM

+++ ACC aaaa AREA=a RF POINT=ppp

Bosch Security Systems, Inc. 1/07 4998122703-01

137

Page 137
Image 137
Bosch Appliances D6100, D6600 C.1 Zonex and Comex Translation, Point to Zonex Translation, User ID to Comex Translation