Bosch Appliances D6600 Modem IIIa2 Messages continued, Bosch Security Systems, Inc. | 1/07, Comex

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 96
Image 96
in item Log % Full

Conettix D6600/D6100 Computer Interface Manual Appendix C: Modem IIIa2 Messages

Table 92: Modem IIIa2 Messages (continued)

 

 

 

 

 

 

 

 

Event

Device/Mode

Display

 

Explanation

Refer to Section

 

 

 

 

 

 

C.1 Zonex and

 

 

 

 

 

 

Comex

 

 

 

 

 

 

Translation on

 

 

 

 

 

 

page 137.

 

 

 

 

 

 

 

400.

Late Opening

Printer:

dd/dd tt:tt Lxx ACC aaaa

LATE TO OPEN

A user with the ID in

1.

 

By Account

 

+++ ACC aaaa

ID=iii

the second line of the

 

 

 

D6500 Mode:

h1rrlssssssaaaasOsiiit

 

report disarmed the

 

 

 

SIA Mode:

<header>[#aaaaNidiiiOJ]

 

AREA after the

 

 

 

 

 

 

programmed opening

 

 

 

 

 

 

time window.

 

 

 

 

 

 

 

 

401.

Late Opening

Printer:

dd/dd tt:tt Lxx ACC aaaa

LATE TO OPEN

A user with the ID in

1,

 

By Account

D6500 Mode:

h1rrlssssssaaaasOsssst

 

the second line of the

D7112

 

(ID not

SIA Mode:

<header>[#aaaaNOJ]

 

report disarmed the

 

 

 

 

reported)

 

 

 

AREA after the

 

 

 

 

 

 

programmed opening

 

 

 

 

 

 

time window.

 

 

 

 

 

 

 

 

402.

Late Opening

Printer:

dd/dd tt:tt Lxx ACC aaaa

LATE TO OPEN

A user with the ID in

1,

 

By Area

 

+++ ACC aaaa

AREA=a ID=iii

the second line of the

D7112

 

 

D6500 Mode:

h1rrlssssssaaaasOsiiit

 

report disarmed the

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNria/idiiiOJ]

AREA after the

 

 

 

 

 

 

programmed opening

 

 

 

 

 

 

time window.

 

 

 

 

 

 

 

 

403.

Late Opening

Printer:

dd/dd tt:tt Lxx ACC aaaa

LATE TO OPEN

A user with the ID in

1,

 

By Area

 

+++ ACC aaaa

AREA=a

the second line of the

D7112

 

(ID not

D6500 Mode:

h1rrlssssssaaaasOsssst

 

report disarmed the

 

 

 

 

reported)

SIA Mode:

<header>[#aaaaNriaOJ]

 

AREA after the

 

 

 

 

 

 

programmed opening

 

 

 

 

 

 

time window.

 

 

 

 

 

 

 

 

404.

Late To Close

Printer:

dd/dd tt:tt Lxx ACC aaaa

CLOSING LATE

 

 

 

(7112 Only)

D6500 Mode:

h1rrlssssssaaaasCsssst

 

 

 

 

 

SIA Mode:

<header>[#aaaaNCJ]

 

 

 

 

 

 

 

 

 

 

405.

Late To Open

Printer:

dd/dd tt:tt Lxx ACC aaaa

LATE TO OPEN

 

 

 

(7112 Only)

D6500 Mode:

h1rrlssssssaaaasOsssst

 

 

 

 

 

SIA Mode:

<header>[#aaaaNOJ]

 

 

 

406.

Listen In

Printer:

dd/dd tt:tt Lxx ACC aaaa

LISTEN IN

 

 

 

 

D6500 Mode:

h1rrlssssssaaaas*sssst

 

 

 

 

 

SIA Mode:

<header>[#aaaaNLF]

 

 

 

 

 

 

 

 

 

 

407.

Listen In

Printer:

dd/dd tt:tt Lxx ACC aaaa

LISTEN jj

 

 

 

 

D6500 Mode:

h1rrlssssssaaaas*sssst

 

 

 

 

 

SIA Mode:

<header>[#aaaaNLF]

 

 

 

 

 

 

 

 

 

 

408.

Log Threshold

Printer:

dd/dd tt:tt Lxx ACC aaaa

LOG THRESHOLD

The log in the control

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsD01t

 

panel reached the

 

 

 

SIA Mode:

<header>[#aaaaNJL]

 

programmed percent

 

 

 

 

 

 

full point programmed

 

 

 

 

 

 

in item Log % Full

 

 

 

 

 

 

(default Log Full =

 

 

 

 

 

 

85%).

 

 

 

 

 

 

 

 

409.

Log Overflow

Printer:

dd/dd tt:tt Lxx ACC aaaa

LOG OVERFLOW

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasAsD01t

 

 

 

 

 

SIA Mode:

<header>[#aaaaNJO]

 

 

 

410.

Log Overflow

Printer:

+++ ACC aaaa

LOG OVERFLOW

The log in the control

5.

 

Since Last Call

D6500 Mode:

h1rrlssssssaaaaSLsssst

 

panel reached the

 

 

 

SIA Mode:

<header>[#aaaaOJO]

 

programmed percent

 

 

 

 

 

 

full point programmed

 

 

 

 

 

 

in item Log % Full

 

 

 

 

 

 

(default Log Full =

 

 

 

 

 

 

85%).

 

 

 

 

 

 

 

 

411.

Log Threshold

Printer:

+++ ACC aaaa

LOG THRESHOLD

 

5.

 

Since Last Call

D6500 Mode:

h1rrlssssssaaaaSBsssst

 

 

 

 

 

SIA Mode:

<header>[#aaaaOJL]

 

 

 

96

Bosch Security Systems, Inc. 1/07 4998122703-01

Page 96
Image 96
Bosch Appliances D6600, D6100 Modem IIIa2 Messages continued, Bosch Security Systems, Inc. | 1/07, C.1 Zonex and, Comex