Conettix D6600/D6100 Computer Interface Manual

Appendix I:

D6600 SafeCom Messages

 

 

 

Table 112: D6600 SafeCom Messages - Line Card or Account Signals (continued)

 

 

 

 

 

 

 

#

Event

Device/

Display

Notes on Auto

 

 

 

Mode

 

Output

 

 

 

 

 

 

 

 

27.

Silent/Medical Panic

6500

hprrl0aaa03200304t

Only valid for

 

 

 

 

SIA1

<header>[#0aaa03200304]

SC5000

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>SILENT/MEDICAL

 

 

 

 

 

 

PANIC

 

 

28.

Operator Evacuation

6500

hprrl0aaa03200305t

Only valid for

 

 

Bell

SIA1

<header>[#0aaa03200305]

SC5000

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>OPERATOR EVACUATION

 

 

 

29.

Input Normal

6500

hprrl0aaa0320011it

 

 

 

 

 

SIA1

<header>[#0aaa0320011i]

 

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa normal: input i

 

 

30.

Input Open

6500

hprrl0aaa0320021it

 

 

 

 

 

SIA1

<header>[#0aaa0320021i]

 

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>OPENED: input i

 

 

 

 

 

 

 

 

 

31.

Input Short

6500

hprrl0aaa0320031it

 

 

 

 

 

SIA1

<header>[#0aaa0320031i]

 

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>SHORTED: input i

 

 

32.

Input Bypass

6500

hprrl0aaa0320041it

 

 

 

 

 

SIA1

<header>[#0aaa0320041i]

 

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa bypass: input i

 

 

 

 

 

 

 

 

 

33.

Input Unbypass

6500

hprrl0aaa0320051it

 

 

 

 

 

SIA1

<header>[#0aaa0320051i]

 

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa unbypass: input i

 

 

34.

Zone Restore

6500

hprrl0aaa0320011zt

Only valid for

 

 

 

SIA1

<header>[#0aaa0320011z]

SC5000

 

 

 

Printer2

dd/dd tt:tt Sxx aaa restore: zone z

 

 

 

 

 

 

 

 

35.

Zone Trouble

6500

hprrl0aaa0320021zt

Only valid for

 

 

 

 

SIA1

<header>[#0aaa0320021z]

SC5000

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>TROUBLE: zone z

 

 

36.

Fire Alarm

6500

hprrl0aaa0320031zt

Only valid for

 

 

 

SIA1

<header>[#0aaa0320031z]

SC5000,

 

 

 

 

 

depending on the

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>FIRE: zone z

 

 

 

 

 

zone type

 

37.

Silent Alarm

6500

hprrl0aaa0320031zt

Only valid for

 

 

 

 

SIA1

<header>[#0aaa0320031z]

SC5000,

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>SILENT: zone z

depending on the

 

 

 

 

 

 

zone type

 

38.

Burglary Alarm

6500

hprrl0aaa0320031zt

Only valid for

 

 

 

SIA1

<header>[#0aaa0320031z]

SC5000,

 

 

 

Printer2

dd/dd tt:tt Sxx aaa>BURGLARY: zone z

depending on the

 

 

 

 

 

zone type

 

39.

Zone Bypass

6500

hprrl0aaa0320041zt

Only valid for

 

 

 

 

SIA1

<header>[#0aaa0320041z]

SC5000

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa BYPASS: zone z

 

 

40.

Zone Unbypass

6500

hprrl0aaa0320051zt

Only valid for

 

 

 

SIA1

<header>[#0aaa0320051z]

SC5000

 

 

 

 

 

 

 

 

 

 

Printer2

dd/dd tt:tt Sxx aaa unbypass: zone z

 

 

1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165.