Bosch Appliances D6100, D6600 Appendix A Contact ID Event Code Classifications, Contact ID format

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 53
Image 53
Appendix A: Contact ID Event Code Classifications

Conettix D6600/D6100 Computer Interface Manual Appendix A: Contact ID Event Code Classifications

Appendix A: Contact ID Event Code Classifications

Figure 24: Contact ID format

1 2 3 4 5

1234 E 123 01 123

1 - Customer (Subscriber Account Number)

2 - Event Qualifier - E = New Event, R = Restore

3 - Event Code - refer to Section A1 Event Codes 4 - Partition Number, 00 to 08 (always 00 for non-

partitioned panels)

5 - Zone ID number* - reporting the alarm (001 to

999) or user number for open or close reports.

* System status messages, such as AC Loss and Low Battery, are Zone ID 000.

Table 90: Event Codes

 

 

 

#

Event Type

Zone

Medical:

 

100

Medical

Emerg-Personal Emergency-#

101

Pendant

Emerg-Personal Emergency-#

 

Transmitter

 

102

Fail to report in

Emerg-Fail to check in-#

Fire Alarms:

 

110

Fire

Fire-Fire Alarm-#

111

Smoke

Fire-Fire Alarm-#

 

w/Verification

 

112

Combustion

Fire-Combustion-#

113

Waterflow

Fire-Water Flow-#

114

Heat

Fire-Heat Sensor-#

115

Pull Station

Fire-Pull Station-#

116

Duct

Fire-Duct Sensor-#

117

Flame

Fire-Flame Sensor-#

 

 

 

118

Near Alarm

Fire-Near Alarm-#

 

 

 

Panic Alarms:

 

120

Panic Alarm

Panic-Panic-#

121

Duress

Panic-Duress-User #

122

Silent

Panic-Silent Panic-#

123

Audible

Panic-Audible Panic-#

124

Duress-Access

Panic-Duress Access Grant-#

 

Granted

 

 

 

 

125

Duress-Egress

Panic-Duress Egress Grant-#

 

Granted

 

Table 90: Event Codes (continued)

 

 

 

#

Event Type

Zone

 

 

 

Burglar Alarms:

 

130

Burglary

Burg-Burglary-#

131

Perimeter

Burg-Perimeter-#

132

Interior

Burg-Interior-#

133

24 HR Burg (Aux)

Burg-24 Hour-#

134

Entry/Exit

Burg-Entry/Exit-#

135

Day/Night

Burg-Day/Night-#

136

Outdoor

Burg-Outdoor-#

 

 

 

137

Tamper

Burg-Tamper-#

 

 

 

138

Near Alarm

Burg-Near Alarm-#

139

Intrusion Verifier

Burg-Intrusion Verifier-#

General Alarms:

 

140

General Alarm

Alarm-General Alarm-#

141

Polling Loop

Alarm-Polling Loop Open

 

Open

 

 

 

 

142

Polling Loop

Alarm-Polling Loop Short

 

Short (AL)

 

143

Expansion Mod

Alarm-Exp. Module Tamper-#

 

Failure

 

144

Sensor Tamper

Alarm-Sensor Tamper-#

145

Expansion Module

Alarm-Exp. Module Tamper-#

 

Tamper

 

 

 

 

146

Silent Burg

Alarm-Silent Burglary-#

 

 

 

Bosch Security Systems, Inc. 1/07 4998122703-01

53

Page 53
Image 53
Bosch Appliances D6100 Appendix A Contact ID Event Code Classifications, Contact ID format, 1 2 3 4, partitioned panels