Bosch Appliances D6600, D6100 manual Bosch Security Systems, Inc. | 1/07

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 54
Image 54
Manual background

Conettix D6600/D6100 Computer Interface Manual Appendix A: Contact ID Event Code Classifications

Table 90: Event Codes (continued)

 

 

 

 

#

Event Type

Zone

 

 

 

 

 

24 Hour Non-Burglary:

 

150

24 Hour (Auxiliary

Alarm-24 Hr. Non-Burg-#

151

Gas Detected

Alarm-Gas Detected-#

152

Refrigeration

Alarm-Refrigeration-#

153

Loss of Heat

Alarm-Heating System-#

154

Water Leakage

Alarm-Water Leakage-#

155

Foil Break

Trouble-Foil Break-#

 

 

 

156

Day Trouble

Trouble-Day Zone-#

 

 

 

157

Low Bottled Gas

Alarm-Low Gas Level-#

 

 

Level

 

158

High Temp

Alarm-High Temperature-#

159

Low Temp

Alarm-Low Temperature-#

161

Loss of Air Flow

Alarm-Air Flow-#

 

 

 

162

Carbon Monoxide

Alarm-Carbon Monoxide-#

 

 

Detected

 

163

Tank Level

Trouble-Tank Level-#

Fire Supervisory:

 

200

Fire Supervisory

Super.-Fire Supervisory-#

201

Low Water

Super.-Low Water Pressure-#

 

 

Pressure

 

202

Low CO2

Super.-Low CO2-#

203

Gate Valve

Super.-Gate Valve-#

 

 

Sensor

 

 

 

 

204

Low Water Level

Super.-Low Water Level-#

205

Pump Activated

Super.-Pump Activation-#

206

Pump Failure

Super.-Pump Failure-#

System Troubles:

 

300

System Trouble

Trouble-System Trouble

301

AC Loss

Trouble-AC Power

302

Low System Batt

Trouble-Low Battery

303

RAM Checksum

Trouble-Bad RAM Checksum

 

 

Bad

(Restore not applicable)

304

ROM Checksum

Trouble-Bad ROM Checksum

 

 

Bad

(Restore not applicable)

 

 

 

305

System Reset

Trouble-System Reset (Restore

 

 

 

not applicable)

306

Panel Prog

Trouble-Programming Changed

 

 

Change

(Restore not applicable)

 

 

 

307

Self-Test Failure

Trouble-Self Test Failure

 

 

 

308

System

Trouble-System Shutdown

 

 

Shutdown

 

309

Battery Test Fail

Trouble-Battery Test Failure

310

Ground Fault

Trouble-Ground Fault-#

 

 

 

311

Battery Missing

Trouble-Battery Missing

 

 

 

312

Power Supply

Trouble-Pwr. Supp. Overcur.-#

 

 

Overcurrent

 

313

Engineer Reset

Status-Engineer Reset-User #

 

 

 

(Restore not applicable)

 

 

 

 

Table 90: Event Codes (continued)

 

 

 

 

 

 

 

 

 

 

 

#

Event Type

Zone

 

 

 

 

 

 

 

Sounder/Relay Troubles:

 

 

320

Sounder/Relay

Trouble-Sounder/Relay-#

 

 

 

 

 

321

BELL 1

Trouble-Bell/Siren #1

 

322

BELL 2

Trouble-Bell/Siren #2

 

323

Alarm Relay

Trouble-Alarm Relay

 

324

Trouble Relay

Trouble-Trouble Relay

 

325

Reversing Relay

Trouble-Reversing Relay

 

326

Notification

Trouble-Notification Appl.

 

 

 

Appliance CKT. #3

Ckt#3

 

327

Notification

Trouble-Notification Appl.

 

 

 

Appliance CKT. #4

Ckt#4

 

 

 

 

 

System Peripheral Troubles:

 

 

330

System Peripheral

Trouble-Sys. Peripheral-#

 

 

 

 

 

331

Polling Loop Open

Trouble-Polling Loop Open

 

 

 

 

 

332

Polling Loop Short

Trouble-Polling Loop Short

 

333

Exp. Module Failure

Trouble-Exp. Module Fail-#

 

334

Repeater Failure

Trouble-Repeater Failure-#

 

335

Local Printer Paper

Trouble-Printer Paper Out

 

 

 

Out

 

 

 

 

 

 

336

Local Printer Failure

Trouble-Local Printer

 

337

Exp. Mod. DC Loss

Trouble-Exp. Mod. DC Loss-#

 

338

Exp. Mod. Low bat

Trouble-Exp. Mod. Low Batt-#

 

339

Exp. Mod. Reset

Trouble-Exp. Mod. Reset-#

 

341

Exp. Mod. Tamper

Trouble-Exp. Mod. Tamper-#

 

342

Exp. Module AC

Trouble-Exp. Module AC

 

 

 

Loss

Loss-#

 

343

Exp. Module Self

Trouble-Exp. Self-Test Fail-#

 

 

 

Test Fail

 

 

344

RF Rcvr Jam Detect

Trouble-RF Rcvr Jam Detect-

 

 

 

#

#

 

Communication Troubles:

 

 

350

Communication

Trouble-Communication

 

 

 

 

Failure

 

 

 

 

 

351

Telco 1 Fault

Trouble-Phone line #1

 

 

 

 

 

352

Telco 2 Fault

Trouble-Phone line #2

 

353

LR Radio Xmitter

Trouble-Radio Transmitter

 

 

 

Fault

 

 

354

Failure To

Trouble-Fail to Communicate

 

 

 

Communicate

 

 

355

Loss of Radion

Trouble-Radio Supervision

 

 

 

Super.

 

 

 

 

 

 

356

Loss of Central

Trouble-Central Radion

 

 

 

Polling

Polling

 

357

LRR XMTR. VSWR

Trouble-Radio Xmitter.

 

 

 

 

VSWR-#

 

 

 

 

 

54

Bosch Security Systems, Inc. 1/07 4998122703-01

Page 54
Image 54
Bosch Appliances D6600, D6100 manual Bosch Security Systems, Inc. | 1/07