3.1.6ADT SIA (Message Type S)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

3.1.6ADT SIA (Message Type S)

ADT SIA

 

D6500 Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

 

 

 

 

 

 

 

 

 

 

 

h

S

r

r

l

[

#

a

a

a

a

d

a

m

m

-

d

d

-

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

 

 

 

 

y

t

I

h

h

:

m

m

:

s

s

E

M

M

Z

Z

Z

Z

/ ** t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 8:

 

ADT SIA (Message Type S) Byte Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

Title

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

S

3-4

Receiver Number

Receiver gateway number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6

 

 

space

 

One space.

7

 

#

 

#

8-11

 

 

Account Number

 

Up to sixteen digits in the account number.

12

 

 

 

Separator. Indicates more data positions after account number.

 

 

 

 

 

 

 

 

 

13-32

 

 

Date and Time

 

 

Date and time.

33

 

 

E

 

SIA block code.

34-35

 

 

Event Code

 

SIA event code (refer to Appendix G ADT SIA Report Codes on page 149).

36-39

 

 

Zone

 

Zone number.

 

 

 

 

 

 

40

 

/

 

 

Separator.

41

 

***

 

 

Next block of data.

42

 

 

Trailer Character

 

Typically, this is HEX 14.

3.1.7Caller ID (Message Type e)

Caller ID Example

D6500 Byte Description

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

h e r r 1 T T T T T T T T T T T T T T T T t

Table 9: Caller ID (Message Type e) Byte Description

#

Title

Description

1Header Character (h) Optional. Check with the computer automation software for compatibility.

2

Message Type

e

3-4

Receiver Number

Receiver gateway Number from 01 to 99.

 

 

 

5Line/Group Number Line number in the receiver gateway that sent the message.

6-21

Caller ID

Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with

 

 

leading ASCII spaces.

22

Trailer Character

Typically, this is HEX 14.