Bosch Appliances D6100, D6600 Internal Messages continued, Bosch Security Systems, Inc. | 1/07

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 59
Image 59
Table 91: Internal Messages (continued)

Conettix D6600/D6100 Computer Interface Manual Appendix B: Internal Messages

Table 91: Internal Messages (continued)

 

 

 

 

 

 

#

Internal Messages

D6500

SIA

Printer Output

 

 

Output2

Output2

 

39.

System Reset

X 37

[NYW01]

SYSTEM RESET

40.

System Default1

X 38

[NYG]

SYSTEM DEFAULT

 

 

 

 

 

41.

System Temperature High

X 39

[NKA]

SYSTEM TEMPERATURE HIGH

42.

System Temperature Restore

X 40

[NKR]

SYSTEM TEMPERATURE RESTORE

43.

Slotx/Linex (Lxx) Line Fault

X

5

[NLT]

PHONE LINE FAULT

44.

Slotx/Linex (Lxx) Line Restore

X

6

[NLR]

PHONE LINE RESTORE

45.

Slotx/Linex (Lxx) Line Card

X

7

[NYD]

LINE CARD TROUBLE

 

Trouble

 

 

 

 

46.

Slotx/Linex (Lxx) Line Card

X

8

[NYE]

LINE CARD RESTORE

 

Restore

 

 

 

 

47.

Slotx/Linex (Lxx) Audio In

*

 

[NLF]

AUDIO IN

48.

Slotx/Linex (Lxx) Audio Done

L

 

[NLE]

AUDIO DONE

49.

Slotx/Linex (Lxx)

X 60

[NUA03]

COMMUNICATION ERROR

 

Communication Error1

 

 

 

 

50.

Slotx/Linex (Lxx)

X 61

[NUR03]

COMMUNICATION RESTR

 

Communication Restr1

 

 

 

 

51.

Slotx/Linex (Lxx) Data Error

X 62

[NYN]

DATA ERROR

52.

Slotx/Linex (Lxx) No Data

X 63

[NUT04]

NO DATA RECEIVED

 

Received

 

 

 

 

53.

Slotx/Linex (Lxx) Reset

X 64

[NYW02]

RESET

54.

Slotx/Linex (Lxx) Codec Error1

X 65

[NUT05]

CODEC ERROR

55.

Slotx/Linex (Lxx) Private Call

P

 

[NUT06]

PRIVATE CALL

56.

Slotx/Linex (Lxx) No Call

N

 

[NUT07]

NO CALL NUMBER

 

Number

 

 

 

 

57.

Slotx/Linex (Lxx) Caller

U

 

[NUT08]

CALLER UNKNOWN

 

Unknown

 

 

 

 

58.

Set Date

X 51

[NJD]

DATE SET

59.

Stop Two Way Audio

X 52

[CLK]

TWO WAY AUDIO STOP

60.

CPU Data Error1

X 53

[NYN01]

CPU DATA ERROR

 

 

 

 

 

61.

Network Error1

X 54

[NNT]

NETWORK TROUBLE

62.

Network Restore1

X 55

[NNR]

NETWORK RESTORE

63.

Account Status Failure

T B02

[NYC]

COMMUNICATIONS FAILURE

64.

Account Status Restore

N B02

[NYK]

COMMUNICATIONS RESTORED

 

 

 

 

 

65.

Supervision Rate Changed

X 66

[NCO0001]

SUPERVISION RATE CHANGED

66.

Switch To Intercept Mode

X 88

[NCO0002]

SWITCH TO INTERCEPT MODE

67.

Switch to Fallback Mode

X 81

[NCO0003]

SWITCH TO FALLBACK MODE

68.

Diable Intercept Mode

X 83

[NCO0004]

DISABLE INTERCEPT MODE

 

 

 

 

 

69.

Activate Output

X 84

[NCO0005]

ACTIVATE OUTPUT

70.

Deactivate Output

X 86

[NCO0006]

DEACTIVATE OUTPUT

71.

C900 Reboot

X 59

[NSC0001]

C900 REBOOT

72.

C900 Battery Low

X 58

[NSC0002]

C900 BATTERY LOW

73.

C900 Battery Restore

X 68

[NSC0003]

C900 BATTERY RESTORE

74.

C900 Switched to Intercept

X 87

[NSC0004]

C900 SWITCHED TO INTERCEPT

75.

C900 Switched to Fallback

X 82

[NSC0005]

C900 SWITCHED TO FALLBACK

76.

C900 Output Activated

X 85

[NSC0006]

C900 OUTPUT ACTIVATED

1

2

Internal message is not implemented.

Output messages are abbreviated.

Bosch Security Systems, Inc. 1/07 4998122703-01

59

Page 59
Image 59
Bosch Appliances D6100, D6600 manual Internal Messages continued, Bosch Security Systems, Inc. | 1/07